50A55-5165 Replaces:
Trane
White-Rodgers
CNT03076
50A65-474
CNT03798
50A65-475
CNT05164
50A65-476
CNT05165
D341213P01
D341396P01
D341396P03
D341396P04
D341396P05
TRANE 
INTEGRATED HSI MODULE
DIRECT 
REPLACEMENT
CROSS REFERENCE
Model 
Number
Pre-Purge 
Time
Heat Delay-
To-Fan-On
Heat Delay- 
To-Fan-Off
Cool Delay- 
To-Fan-On 
Cool Delay- 
To-Fan-Off 
Post 
Purge
50A65-5165
0 sec
45
60 / 100 / 140 / 180 
2
0 / 80
5 sec
50A65-5165 TRANE SINGLE STAGE 80V IGNITION 
INTEGRATED HSI FURNACE CONTROL
Controls Gas Valve, Ignitor, Blower, Inducer, Humidifier (120V),
and Air Cleaner. Replaces OEM Trane and White-Rodgers Models
FEATURES
• Includes flash code diagnostics.
• Twinning connection.
• Fused to protect low voltage system transformers.
SPECIFICATIONS
Operating Temperature. . . . . . . . . . . . . . . . . . .   -40 to 176°F
Humidity Range  . . . . . . . . . . . . . . . . . . . . . . . .   5% to 93% RH (non-condensing)
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Snap in standoffs
Electrical Ratings @ 77°F (25°C)
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . .   25 VAC 50 / 60 Hz
Maximum Input Current @ 30 VAC  . . . . . . . . .   0.45 amp
Relay Load Ratings
Valve Relay. . . . . . . . . . . . . . . . . . . . . . . . . . . .   1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf
Ignitor Relay . . . . . . . . . . . . . . . . . . . . . . . . . . .   2.0 amp @ 120 VAC 50 / 60 Hz
Inducer Relay . . . . . . . . . . . . . . . . . . . . . . . . . .   2.2 FLA-3.5 LRA @ 120 VAC
Circulator Relay  . . . . . . . . . . . . . . . . . . . . . . . .   14.5 FLA-25.0 LRA @ 120 VAC
Flame Current Requirements
Minimum current to insure flame detection. . . .   1 uA DC
Maximum current for non-detection  . . . . . . . . .   0.10 uA DC
Maximum allowable leakage resistance. . . . . .   100 M ohms
Timing Spec (@ 60 Hz)                                       maximum
Flame establishing time  . . . . . . . . . . . . . . . . . .   0.8 sec 
Flame failure response time . . . . . . . . . . . . . . .   2.0 seconds
NOTE: At 50 Hz, all timing specifications should be increased by 20%.
NOTE: Can also use Universal Kit 50M56U-843
50A55-5165
New
www.white-rodgers.com
54
HEA
TING