Unigreen Trolleys and Barrows 사용자 설명서

다운로드
페이지 28
24
25
8.  DISMANTLING AND DISPOSAL
Only trained personnel are allowed to dismantle the appliance in accordance with the current 
regulations in the country where it is installed.
     
 CAUTION
•  Before disposing of the appliance, make sure it is no longer possible to operate it, by cutting 
the power supply cable for example. Make sure all its parts are now inoffensive, as they 
could prove to dangerous to children playing.
9.  PROBLEMS, CAUSES AND SOLUTIONS
     
 CAUTION
•  Before taking any steps, follow the instructions in the “Switching off” section. If it is not 
possible to restore correct operation of the appliance using the information in the table 
below, contact a Skilled Technician.
PROBLEM
The combustion engine does not start 
or does not work properly during 
operation.
When the switch is pressed, the 
electric motor does not start or stops 
during use.
If switch is turned, the electric 
motorhums but does not start up.
The pump does not prime.
The pump does not reach maximum 
pressure.
Pressure and flow are irregular 
(buttons).
Excessive vibration in delivery circuit.
Excessive noise associated with 
dropin the oil level.
Excessive consumption of oil  and/or 
oil is whitish colour (presence of 
waterin oil)
CAUSE
Refer to the operating 
andmaintenance instructions for 
thecombustion engine.
A safety device has cut in on the 
system where the appliance is 
connected (fuse, differential circuit 
breaker, etc).
The plug on the power cord is 
notinserted correctly.
The electrical system and / or 
extension cord are not suitable.
Air intake.
Adjustment valve positioned 
underpressure.
The pressure adjustment knob (29) 
isnot screwed down sufficiently.
The lever (30) is in BY-PASS 
position.
Bottlenecks in intake circuit.
The nozzle is worn or is too big.
Air intake
Pressure accumulator not correctly 
inflated.
Bottlenecks in intake circuit.
Rupture of one or more diaphragms.
SOLUTION
Refer to the operating and 
maintenance instructions for the 
combustion engine.
Reset the protection device.If it cuts in 
again, do not use the appliance and 
contact a Skilled Technician.
Take the plug out of the socket 
andinsert it correctly.
Follow instructions in the “Controls and 
connection to mains electricity”section.
Check the intake circuit is intact.
Set pressure to zero with the knob (29) 
(MC 16 only) or by putting thepump in 
bypass with the lever (30).
Turn the knob clockwise until 
therequired pressure is reached.
Put the lever (30) in PRESS position.
Check the intake circuit (above all ifthe 
intake filter is clean).
Replace the nozzle (refer toinstructions 
in the “Spraying” section).
Check the intake circuit is intact.
Restore correct inflation (refer 
toinstructions in the “Preliminary 
procedures” section).
Check intake circuit (above all if 
theintake filter is clean).
Refer to instructions in the“Diaphragm 
Rupture” section.