Siemens AC75 사용자 설명서

다운로드
페이지 569
AC75 AT Command Set  
21.2 AT^SJNET
s
AC75_ATC_V01.002
Page 523 of 569
10/30/06
Confidential / Released
 
Parameter Description
“none“
(P)
No bearer specified
“csd“
Dialup access uses Circuit Switched Data connection
“gprs“
Dialup access via GPRS
““
(P)
The content of parameter 
.
The parameter is global for all interfaces, volatile and will not be reset by 
• If 
 is "csd", then parameter specifies the dialup phone
number. The phone number can be modified to select between ISDN and
anlaog call and to choose a bitrate. See also examples below. 
- The first character added to the phone number selects the mode: i =
ISDN call, a = analog call (default). If omitted the default setting "analog"
applies.
- The last character appended to the phone number determines the
bitrate. If omitted the default setting "9600 bps" applies. 
h = 14400 bps
m = 9600 bps (default)
l = 4800 bps
s = 2400 bps 
• If 
 is "gprs", then parameter specifies the GPRS
access point name. 
““
(P)
Specifies the login name for access to the dialup network. 
Parameter is global for all interfaces, volatile and will not be reset by 
““
(P)
Specifies the password for access to the dialup network. 
Parameter is global for all interfaces, volatile and will not be reset by 
““
(P)
Specifies the Primary DNS server (Nameserver) for the dialup network. The
server address has to be specified in dotted IP address format (e.g.
145.146.147.148). If the parameter is omitted, the DNS assigned by the net-
work is used. 
It is recommended to set manual DNS server addresses rather than using
automatic DNS assignment. This avoids problems in case the network is
unable to properly handle the automatic DNS service. 
Parameter is global for all interfaces, volatile and will not be reset by 
Idle Timeout in seconds
0
(P)
...[30]...21600
Specifies the Java network idle timeout, which is the number of seconds to wait
before the network connection is terminated automatically when no data trans-
fer or other network activities take place. The value 0 means no timeout at all
(you have to terminate a Circuit Switched Data connection using 
 and a
GPRS connection using 
=0). 
We recommend to use values greater than 10 seconds because otherwise you
may get unintentional timeouts for slow network connections. 
Parameter is global for all interfaces, volatile and will not be reset by 
<bearer service>
(str)(+CSCS)
<entry point>
(str)(+CSCS)
<login>
(str)(+CSCS)
<password>
(str)(+CSCS)
<dns>
(str)(+CSCS)
<timeout>
(num)