Amp1 EG
These parameters let you create time‐varying changes in the
volume of oscillator 1.
volume of oscillator 1.
Envelope
These parameters specify how the amp 1 EG will change
over time.
over time.
Amp EG
Level
Start
[00...99]
This sets the initial volume level at note‐on.
Attack
[00...99]
This sets the level at the end of the Attack time.
Break
[00...99]
Break, short for Break Point, sets the level at the end of the
Decay time.
Decay time.
Sustain
[00...99]
This sets the level at the end of the Slope time. Once it
reaches the Sustain level, the EG will stay there until note‐
off (unless it is reset via AMS).
reaches the Sustain level, the EG will stay there until note‐
off (unless it is reset via AMS).
Time
Higher values mean longer times, as shown below.
Attack
[00...99]
This sets how long the EG takes to move from the Start level
to the Attack level.
For the fastest possible attack time, you can set the Start
level to +99; in this case, the EG will start instantaneously at
its maximum value.
to the Attack level.
For the fastest possible attack time, you can set the Start
level to +99; in this case, the EG will start instantaneously at
its maximum value.
Decay
[00...99]
This sets the time it takes to move from the Attack level to
the Break level.
the Break level.
Slope
[00...99]
This sets how long the EG takes to move from the Break
level to the Sustain level. Once it reaches the Sustain level,
the EG will stay there until note‐off (unless it is reset via
AMS).
level to the Sustain level. Once it reaches the Sustain level,
the EG will stay there until note‐off (unless it is reset via
AMS).
Release
[00...99]
This sets how long it takes the EG to move from the Sustain
level to silence.
level to silence.
Curve
Attack
[0L (Linear), 1...9, 10E (Exp/Log)]
This sets the curvature of the Attack segment ‐ the transition
from the Start level to the Attack level.
from the Start level to the Attack level.
Decay
[0L (Linear), 1...9, 10E (Exp/Log)]
This sets the curvature of the Decay segment ‐ the transition
from the Attack level to the Break level.
from the Attack level to the Break level.
Slope
[0L (Linear), 1...9, 10E (Exp/Log)]
This sets the curvature of the Slope segment ‐ the transition
from the Break level to the Sustain level.
from the Break level to the Sustain level.
Attack
Time
Decay
Time
Release
Time
Attack
Level
Sustain
Level
Break
Level
Slope
Time
Start
Level
Level
Note-on or reset
Note-off
Volume
Time
EG Value
Actual Time
10
10 ms
20
44 ms
30
104 ms
40
224 ms
50
464 ms
60
944 ms
70
1.8 seconds
80
3.8 seconds
90
10.9 seconds
99