Overview of the Test Set’s Built-In Tools
Using RF Tools Program
Swept Return Loss
This test radiates a test signal when testing antennas or cables with 
antennas attached to them. Verify that the level and frequency span 
used for the test cannot result in interference to other nearby antennas. 
To minimize interference when running the program, set the power 
level at the DUPLEX OUT port to the minimum value needed for good 
measurement resolution. Set the frequency range carefully. 
This test measures the return loss of a cable or device in the swept 
mode. A SWR bridge and two 6 dB pads are connected to the Test Set. 
The pads are used to reduce impedance mismatch errors between the 
SWR bridge and the DUPLEX OUT and ANT IN ports on the Test Set. 
You will be prompted at the start of the test to enter the start and stop 
frequencies. A reference level is measured first with a short or open on 
the DUT port of the SWR bridge. Then the return loss is measured with 
the cable or antenna-under-test. The trace showing return loss over the 
frequency band selected is displayed on the screen. Measured values for 
best and worst case return loss are printed at the top of the screen. 
VSWR can be calculated from the return loss. 
The following formula can be used to determine the VSWR from the 
return loss: 
VSWR
VSWR is sometimes stated as a ratio. For example: 1.2:1 or “one point 
two to one” VSWR. The first number in the ratio is calculated from the 
formula above. The second number in the ratio is always one. 
 
an
 contain some of the values from this calculation.
Table 3-1
Return Loss (0 to 20 dB) to VSWR
Table 3-2
Return Loss (20 to 40 dB) to VSWR
VSWR
1
10
RL
20
----------
+
1
10
RL
20
----------
-----------------------
=
Return  Loss  (dB)
0
2
4
6
8
10
12
14
16
18
20
VSWR
8.7
4.4
3.0
2.3
1.92
1.67
1.50
1.38
1.29
1.22
Return Loss (dB)
20
22
24
26
28
30
32
34
36
38
40
VSWR
1.22
1.17
1.13
1.11
1.08
1.07
1.05
1.04
1.03
1.03
1.02