Hitachi Flooring NT50AGF 사용자 설명서

다운로드
페이지 102
— 19 —
English
ADJUSTING AIR PRESSURE
 
WARNING
 Do not exceed  
    115 psi (8 bar 
    8.1 kgf/cm2)
1) Adjust the air pressure at recommended operating pressure 90-
115 psi (6.2 - 7.9 bar   6.3 - 8.1 kgf/cm2) according to the length of 
fasteners and hardness of workpiece.
The correct air pressure is the lowest pressure which will do the 
job. Using the Tool at a higher than required air pressure unneces-
sarily over stresses the Tool.
LOADING NAILS
 
WARNING
   When loading nails into the Nailer, 
 
1) Do not contact the ram cap.
 
2) Do not depress the safety trigger; and
 
3) Keep the nailer pointed downward.
Insert Nails into the Nail Rail as 
shown.  Pull back the Pusher 
Bracket (Ref. No. 59) to engage and 
position the Pusher Finger (Ref. No. 
49) behind the loaded Nail Clip(s).  
This will provide pressure against 
the nails and move them into the 
proper position for the nailing func-
tion of the tool. 
IMPORTANT! For best results, 
maintain at lease a 1-2 inch length 
clip of nails in the Magazine Nail 
Rail.