Hitachi Flooring NT50AGF 사용자 설명서

다운로드
페이지 102
— 29 —
English
SERVICE AND REPAIRS
 
WARNING
   Only service personnel trained by Hitachi, distributor or em-
ployer shall repair the Nailer.
   Use only Hitachi parts supplied or recommended by Hitachi for 
repair.
All quality Nailers will eventually require servicing or replacement 
of parts because of wear from normal use.
In order to achieve the optimal performance of the NT50AGF Pneu-
matic Flooring Nailer, preventative Maintenance is recommended.
Manufacturer recommends replacement & re-greasing the Piston 
O-Ring every 25,000 strokes (25,000 Nails).  This will help prevent 
premature wear and/or damage to the Piston & Cylinder and allow 
the Nailer to be operated at the lower air pressure range. 
Manufacturer recommends replacement & Lubrication of the O-
Rings in the Valve Body Assembly every 100,000 strokes (100,000 
Nails).  Again, this recommendation will help achieve longevity and 
optimal performance of the NT50AGF Pneumatic Flooring Nailer. 
NOTE: 
Specifications are subject to change without any obligation 
on the part of HITACHI.
Maintenance Chart
ACTION
WHY
HOW
Drain air line filter 
daily
Prevent accumulation 
of moisture and dirt.
Open manual petcock.
Clean filter element - 
then blow air through 
filter in direction oppo-
site to normal flow.
Prevent clogging of 
filter with dirt.
Follow manufacturer’s 
instructions.
Clean magazine and 
feeder mechanism.
Prevent a jam.
Blow clean daily.
Keep safety trigger 
working properly.
Promote operator 
safety and efficient 
Tool operation.
Blow clean daily.
Drain air compressor.
Keep the Nailer operat-
ing properly.
Open petcock on air 
compressor tank.