Epson Net 5 사용자 설명서

다운로드
페이지 216
ExposureTime Property 
 
ExposureTime Property 
 
Applies To 
Vision Sequences 
 
Description 
Sets the electronic shutter time for a camera that is running in asynchronous reset mode. 
 
Usage 
VGet  Sequence.ExposureTimevar 
VSet  Sequence.ExposureTimevalue 
Sequence  Name of a sequence or string variable containing a sequence name. 
var 
Long variable that will contain the value of the property. 
value 
Long expression for the new value of the property. 
 
Values 
Long value in microseconds. 
Default: 0 (microsecond) 
 
Remarks 
When RuntimeAcquire is Stationary and ExposureTime = 0, the camera acquires images in Next Frame 
mode.  When the sequence runs, the camera waits for the next valid frame, then acquires the image.   
CameraGain and CameraOffset settings are used.  Typical image acquire time is from 33 to 66 ms for 
SC300 series.   
When RuntimeAcquire is Stationary and ExposureTime is > 0, the camera acquires images in async reset 
mode.  When the sequence runs, the camera sensor is exposed for the ExposureTime, then the image is 
acquired.  CameraGain and CameraOffset settings are not used.  Typical image acquire time is 33 ms + 
Exposure time. 
When RuntimeAcquire is Strobed, ExposureTime must be > 0, and the camera acquires images in async 
reset mode.  After the hardware trigger input is received, the camera sensor is exposed for the 
ExposureTime, then the image is acquired.  CameraGain and CameraOffset settings are not used.  Typical 
image acquire time is 33 ms + Exposure time. 
 
See Also 
RuntimeAcquire Property, CameraGain Property, CameraOffset Property,  Sequence Tab 
50 
Vision Guide 5.0 Reference (Ver.5.3) Rev.1