Weber SUMMIT 450 작동 가이드

다운로드
페이지 20
6
EACH HEAT ZONE OPERATES INDEPENDENTLY.
Summary lighting instructions are on the control panel.
Crossover Ignition System
Note - The Crossover Ignition System ignites the Left
burner of each heat zone with a spark from the igniter
electrode inside the Gas Catcher Ignition Chamber. You
generate the energy for the spark by pushing the
Crossover Ignition Button until it clicks.
WARNING: Check hose before each use of barbecue
for nicks, cracking, abrasions or cuts. If the hose is
found to be damaged in any way, do not use the
barbecue. Contact your dealer.
WARNING:The storage space under the cooking
module is intended for storage of nonflammable
items only.
Figure 1
DA N G E R
Failure  to  open  lid  while  igniting  the
b a r b e c u e, or  not  waiting  5  minutes to  allow
the gas to clear if the barbecue does not light,
m ay  result  in  an  explosive  flame-up  which
can cause serious bodily injury or death.
High
Medium
Low
Off
Crossover Ignition System
1) Open the lid. Figure 1.
2)
Check that the fuel scale reads more than “E”.
Note - E = empty; F = full.
3)
Make sure all burner control knobs are OFF. (Push
each burner control knob down and turn clockwise.)
WARNING: The b urner control knobs must be in the
OFF position before turning on the LP tank valve. If
they are not in the OFF position, when you turn on
the LP tank valve, the excess flow control will
activate, limiting the flow of gas from the LP tank. If
this should occur, turn OFF the LP tank valve and
burner control knobs and start over.
4)
Turn the tank on by turning the tank valve
counterclockwise. 
WA R N I N G : Do not lean over open barbecue. Ke e p
your face and body at least one foot aw ay from the
m a t chlight hole when lighting the barbecue.
5)
Select Heat Zone.
6)
Push LEFT burner control knob down and turn to
START/HI.
7) Push the Crossover Ignition Button several times, so
it clicks each time.
8)
Check that the burner is lit by looking through the
matchlight hole above the burner control knob. 
WARNING: If the burner does not light, turn the LEFT
burner control knob to OFF and wait 5 minutes to let
the gas clear before you try again or try to light with
a match.
9) After the LEFT burner is lit you can turn on the
RIGHT burner.
Note - Always light the LEFT burner first.The RIGHT
burner ignites from the LEFT burner.
TO EXTINGUISH
Turn gas supply OFF at the source, then push down
and turn each burner control knob clockwise to OFF.
DANGER
When the excess flow control is activa t e d ,
a small  amount  of  gas  is  still  flowing  to  the
bu r n e rs . After  turning  OFF  the  tank  and
burner control knobs, wait at least 5 minu t e s
for the gas to clear before attempting to light
the barbecue. Failure  to do so may  result  in
an  explosive  flame-up  which  can  cause
serious bodily injury or death.
LIGHTING