MODELS MDS107, MDS107L, MDS101, MDS 101L
OPERATIONAL SUMMARY
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY,
UL217 BY UNDERWRITERS LABORATORIES, INC.
Blinks On once
approx every
40-45 seconds
Stays On
AC Power is present. DC Power is present.
Blinks On once approx every
40-45 seconds
Off
AC Power is not present and alarm is receiving DC Power. Check the breaker or fuse box for power.
If the breaker or fuse box looks normal, call a licensed electrician for assistance.
Silent
Silent
Blinks On
approx every
2 seconds
Stays On
Nuisance Alarm - If there is no hazard present, verify the alarm is mounted in the correct location
(see User's Manual, "AVOID THESE LOCATIONS" section). Reset alarm as instructed below.
Horn does not
sound when other alarms are active
or horn does not sound when
inter-connected alarm's test
button is pressed
Blinks On once
approx every
40-45 seconds
Stays On
or Off
Press and hold the smoke alarm Test/Silence button for at least 5 seconds. If still no alarm, turn off
AC Power at the circuit breaker or fuse box and disconnect the alarm from the mounting bracket
and make sure the connector plug is securely attached on units that did not alarm. If still no alarm,
have a licensed electrician check to see if the yellow wire is connected to the neutral wire.
Blinks On
approx every
2 seconds
Stays On
Originating Smoke Alarm - If hazard is identified, please take all precautions if an alarm sounds by
calling an Emergency Service and getting out of the home.
Off
Stays On
Non-originating Smoke Alarm - Another interconnected smoke alarm has sensed smoke, causing
all interconnected units to sound.
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks on once approx every
10 seconds
(silence mode)
Stays On
QUICK FIND
®
 Alarm Origination - In an interconnected system, it is difficult to determine which
alarm initiated the alarms to sound. The 
QUICK FIND
®
 feature will allow you to immediately locate
the originating alarm (once  the alarms have stopped sounding). To initiate 
QUICK FIND
®
, press
the Test/Silence  button on any alarm; and, after releasing the button, the originating alarm will
continue to sound for approx 60 seconds. Reset the originating alarm. NOTE: In a non- interconnected
installation, it is necessary to test each alarm to determine the originating alarm.
Blinks On once
approx every
40-45 seconds
Stays On
To Reset the Alarm - Hold the Test/Silence button for approx. 10 seconds. This will clear alarm
origination. Reset after each smoke alarm event.
Silent
1 Chirp approx
 every 40 seconds
Stays On
Low Battery - Check to make sure the battery activation pull tab has been completely removed,
battery polarity is correct and the battery terminals are making contact with the smoke alarm contacts
in the battery drawer. If chirp continues, replace the 9V battery (see User's Manual for recommended
battery types).
Stays On
Silence Feature is activated by pressing and releasing the Test/Silence button on the initiating
alarm while in alarm condition. Silence mode will last for approx 8-12 minutes.
Blinks On
approx every
2 seconds
Silent
(alarmed
previously)
CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS 
BEFORE
 SOLUTION / RECOMMENDATION
SOLUTION / RECOMMENDATION
HORN
RED LED
GREEN LED
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks on once approx every
10 seconds
(silence mode)
Blinks On once
approx every
40-45 seconds
1 Beep approx
every 60 seconds
Stays On
End-of-Service Life alarm. The alarm should be replaced immediately.
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat