Rinnai ES38 (RHFE-1004FTA) 설치 설명서

다운로드
페이지 80
 
 
Rinnai Corporation ES38 Manual 
 
21 
  Drilling 
Flue 
Hole          
 
 
 
 
 
 
 
 
 
Ensure that there are no gas or water lines, or 
electrical circuits in the wall location where the flue 
hole is to be drilled.   
Drill the flue hole using a 3 1/8 inch (80 mm) drill.  A 
template is provided on the appliance carton/box.  
The center of the hole must be located anywhere 
within the shaded area, unless extension kits are 
used.   See the dimensions diagram.   
For weatherboard walls, drill through the center of 
the weatherboard from the outside first and then 
through the plasterboard.   
Flue Hole
3 1/8"
(8
0
 mm)
Attach the wall brackets as shown.  A template is 
provided. 
  Attach Wall Brackets   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  Attach Back Spacers   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Attach side back spacers to both sides of the 
appliance with 2 screws each. 
Template is on the appliance carton/box. 
Wall bracket
28.5 in (723 mm)
1.2 in (30 mm)
23.3 
in
 (
593 m
m
)
0.9 in (24 mm)