Chapter 6: Troubleshooting
78
MMG Installation, Setup, and Operations Guide
Transfer from Liquid blue to MSS Fails
1.
Check the transfer log file named joblogs/info_<jobid>.log to see if either FTP server 
returned a reason for failure. Common reasons for failure and their resolutions are shown in 
the following table.
2.
Search the ConnectPlus 1000 gateway’s log (C:\FSC\logs\fsc.log.0X) for instances of the 
word Fail, which indicates an internal failure of some type, usually a failed communication 
to the FSC or a Fibre Channel failure.
3.
Search the ConnectPlus 1000 gateway for the world truncating. Truncating indicates that the 
size calculated during transfer does not match the size on the FSC. This discrepancy usually 
results from a failure to generate a header for the file, which causes the FSC to register the 
size as zero. If there is no failure message associated with the truncating message, and the 
number of bytes transferred matches the actual size of the file, attempt to retrieve the file so 
that Pinnacle Technical Support can debug the incompatibility. If you cannot retrieve it, retry 
the transfer with the debug flag SANFtpd +io set on the ConnectPlus 1000 gateway, and also 
request the settings with which the file was recorded.
Reason
Resolution
SAN reports a problem with the Fibre 
Channel connection.
Check Fibre Channel cable connections. Unplug and replug them if 
they are already connected. If transfers still fail, reboot the 
ConnectPlus 1000 gateway. If transfers continue to fail, telnet to the 
MSS and check
 
sand_state –s
 to see if one of the arrays or 
switches is malfunctioning. Consult with Pinnacle Technical Support 
before proceeding.
Liquid blue reports access denied.
Check that the FTP server and the Windows OS are both configured 
so that the directory is writable.