6.4.1  Starting the Test 
A  Standalone  Diagnostic  test  requires  a  tape  that  is  not write-protected. The media type can be any 
media type that supports a tape format that can be written by the drive. 
CAUTION: Since the test involves write operations, the existing tape contents will be destroyed! 
1.  Make sure that no cartridge is loaded. 
No cartridge should be loaded at this stage. If a cartridge is loaded it can be ejected by clicking 
the Eject Button. 
2.  Enter Service Mode by keeping the Eject Button pressed for at least 6 seconds.  
The Ready LED (on the left) starts flashing fast (indicating the drive is in Service Mode and that 
Service entry number 1 is active). 
3.  Insert the tape cartridge into the drive within 15 seconds. 
 
The drive loads the cartridge and the Ready LED starts flashing indicating that Standalone 
Diagnostics has started. The eject button has now returned to normal mode. During the 
Standalone Diagnostics test, it is possible to abort the test and eject the cartridge by clicking the 
eject button. The drive indicates the detection of the abort request by flashing both the Ready and 
Activity LEDs. Depending on at which stage the test is aborted, it may take a while before the 
drive starts the eject operation. When the cartridge has been ejected, all LEDs are turned off (the 
Cleaning LED may however be on). 
 
The Ready LED will continue flashing during the complete test. The Activity LED will be 
flashing when the test performs tape motion.  
 
If no cartridge has been inserted after 15 seconds, the LEDs revert back to their initial state and 
the Eject Button must be pressed for 6 seconds again to get back to Service Mode. 
6.4.2  Test Sequence 
The Tandberg LTO HH Standalone Diagnostics test will perform the following operations: 
Collect Information. Reads and stores drive and medium information: 
•  Firmware and Drive ID 
•  Tape type and format 
•  Cartridge serial number 
•  Error History Log and Log page 0x33 from EEPROM 
•  Run-time counters from EEPROM 
 
Mainboard Test. Tests the mainboard hardware.  
Cartridge  Manipulation  Test.  The  Cartridge  Manipulation  Test  performs  the  same  mechanical 
movement operations as those performed during Cartridge Load and Eject.  
Read/Write Test. This test involves actual reading and writing on the tape medium. A write pass and 
a read pass are executed.  
When  the  test  has  completed  without  errors  the  tape  cartridge  is  ejected.  No  LEDs  will  be  lit  (the 
Cleaning LED may however be on). 
6.4.3  Failure Indication 
When a failure has been detected the tape is not ejected and the Failure LED will be flashing. 
Detailed information can be retrieved by the ‘Receive Diagnostic Results’ SCSI command.