3. Operation
3-3 Interpreting beeps and displays
1. Displays and beeps in normal operation
No.
Status 
indicator
Power supply 
output 
lamp
 
Beep
Charging
Description
Solution
1
None
OFF
No AC input.
Operation stopped.
−−
2
None
ON
There is AC input. 
Power switch is OFF.
−−
3
None
ON
Power switch is ON.
Operating normally.
−−
○ 
○ 
● 
○ 
○ 
○ 
Bypass 
operation 
lamp
○ 
○ 
○ 
Battery 
replacement 
lamp
(     indicates blinking)
(     
indicates the display is ON
)
(     
indicates the display is OFF
)
○ 
● 
2. Displays and beeps while testing 
4
None
−−
5
None
−−
OFF
Discharging
Discharging
Self-diagnostic test in progress.
OFF
Auto battery test in progress. 
3. Displays and beeps during power failure or AC input error
6
7
 
OFF
Discharging
OFF
Discharging
Discharging
8
None
 
OFF
In Battery Mode due to power  
failure or AC input error.  
Output will stop if Battery  
Mode continues.
(Same as above.)  
Battery level is low, so output  
will soon stop.
Battery is dead,  
so output stopped.  
(This is displayed only for  
a few seconds.)
Intermittent  
4-second  
intervals
Intermittent  
1-second  
intervals
 
(Same as above.)
Perform shutdown operations  
for the connected devices  
and stop them.
Charge the battery. 
9
None
○ 
○ 
 
○ 
10
None
○ 
○ 
 
○ 
(Same as above.)
(ON)
(ON)
Use within the AC input voltage/ 
frequency range described  
in the specifications. 
→ See Page 88
AC input voltage is too high 
(over). 
 
 
AC input frequency is too high 
(over). 
AC input voltage is too low 
(under). 
 
 
AC input frequency is too low 
(under).
 
4. Displays and beeps when there is an equipment failure
ON 
or 
discharging
ON 
or 
discharging
11
12
Intermittent 
0.5-second 
intervals
Continuous
There are too many connected 
devices and the rated capacity is 
exceeded. If this state continues 
for as long as or longer than the 
times described below, 
commercial power continues 
to be supplied through bypass 
operation (Note 1). 
 ・When connection capacity is 
 at 100% or higher: Bypass 
 operation begins after 10 seconds
・When connection capacity is 
 at 120% or higher: Output stops  
 after 1 minute (Go to No.12)
・When connection capacity is 
 at 140% or higher: Output stops 
 after 10 seconds (Go to No.12)
Reduce the number of connected 
devices until the display appears 
as in status No. 3.
Turn OFF the power switches of 
all devices connected to the unit, 
reduce the number of connected 
devices, and turn the power switch 
back ON again.
Output stopped due to exceeded 
connection capacity.