Technical Data
17
Environmental specifications
Certification
Operating temperature range
–25 °C to +55 °C
Storage temperature range
–40 °C to +85 °C
Relative humidity
5 - 95%, non-condensing
Stationary vibration,
sinusoidal
Displacement: 7.5 mm
Acceleration amplitude: 20 m/s² and 40m/s²
Frequency range: 2-8 Hz, 8-200Hz, 200-500Hz
Stationary vibration, random
Acceleration spectral density (m²/s²):
0.96, 2.88, 0.96
Frequency range:
5-10Hz, 10-200 Hz, 200-500 Hz, 60min/axis
Non-stationary vibration,
including shock
Shock response spectrum I, peak acceleration:
3 shocks in each axis and direction; 300m/s², 11 ms.
Shock response spectrum II, peak acceleration:
3 shocks in each axis and direction; 1000m/s², 6 ms.
Bump
Acceleration: 250 m/s²
Free fall transportation
1.2m
Rolling pitching
transportation
Angle: ±35degrees; period: 8s
Static load
10kPa
Low air pressure/high air
pressure
70kPa/106kPa
Directive
1999/5/EC
EMC: EN 301 489-1
EMC: EN 301 489-7
Safety: EN 60950
GSM 3GPP TS 51.010-1
Tested according to GCF-CC