MTX Audio ABUS-HUB4X8 사용자 설명서

다운로드
페이지 4
ABUS-HUB4X8 Multi-Source Multi-Zone Hub
Audio Input (1) (2) - 
There are four stereo line-level source inputs (2). Each input has individual level adjustments (1) (left and right).
Trigger (3)
 - The trigger is activated when any part of the system is on; its output is 12 volts at 300mA.
Emitter Ports 
(5) (7)
 - Each 
source input 
has its 
routed emitter 
port (5) 
if more 
that one 
component of 
the same 
type is 
used the 
remote control 
commands 
will not be confused. Eg. 2 tuners. There is also a common emitter port (70) to control components that are common to all zones.
Indicators (4) 
(6) (10)
 - The 
green status 
indicator (4) 
is on 
when the 
system (one 
or all 
zones) is 
in operation. 
The red 
emitter indicator 
(6) flashes 
when 
there is an infrared data command passing through the hub. The power indicators (10) indicate when the corresponding power supply is on.
ABUS Outputs 
(8 A 
& B)
 - Each 
of the 
ABUS Outputs 
provides the 
power, audio 
and data 
signals to 
feed a 
Volume 
Control Module. 
There are 
four output 
zones, each 
zone may 
independently select 
from any 
of the 
four sources. 
Each zone 
has two 
outputs bank 
“A” and 
bank “B”. 
One power 
supply is 
supplied 
with the 
hub to 
power the 
outputs for 
one bank. 
A second 
power supply 
can be 
added to 
power the 
second bank 
or alternatively 
the second 
output can 
be 
used as an expansion port to feed one or more single source hubs with expansion capability.
CAUTION: Only 
an approved 
ABUS 4-Room 
Power Supply 
(12) should 
be used. 
Substitutes which 
may appear 
to be 
suitable are 
not recommended 
and 
could void warranty.
DC Power Input Sockets (13) - 
There are two power sockets one for each output bank “A” and “B”.
Data Expansion 
Ports (In/Out) 
(9) - 
Another ABUS-HUB4X8 
may be 
connected to 
this port 
if additional 
zones are 
desired. Up 
to four 
ABUS-HUB4X8   
Multi-Source Multi-Zone 
hubs may 
be connected 
together, providing 
for a 
maximum of 
16 zones. 
CAUTION: The 
Data Expansion 
Ports pass 
the control 
data between multi-source hubs and may not be used for any other purpose.
Note: The data expansion (9) and audio expansion (1
1) ports must be connected to additional hubs for proper function.
Expansion Ports 
(Audio) (1
1) - 
The RCA
 Expansion 
Outputs allow 
expansion of 
the audio 
sources to 
the main 
system amplifi
er or 
to an 
additional ABUS-
HUB4X8 Multi-Source 
Multi-Zone Hub. 
The audio 
levels adjusted 
at the 
input will 
be the 
same on 
the output 
so no 
level adjustments 
will be 
required on 
the additional hubs).
IR Remote 
Control (14)
 - One 
ABUS ABO-41RC 
remote control 
handset is 
supplied with 
the ABUS-HUB4X8 
Multi-Source Multi-Zone 
Hub. This 
remote 
control includes 
a dedicated 
ABUS bank 
and includes 
keys for 
most standard 
functions including 
color cable 
box buttons 
(not used 
in all 
countries). The 
remote control 
has a 
code library 
built in; 
however, it 
is capable 
of providing 
advanced functions 
for user 
convenience. All 
keys have 
learning capability 
including the bank keys; all keys can also learn multiple commands (macros). See separate instructions. 
ABUS-VC3 Keypad Volume Control Module
The ABUS-VC3 
(RJ) Keypad 
Volume 
Control Module 
was designed 
to work 
with in
-
telligent ABUS 
Multi-Source Multi-Zone 
Hubs using 
standard ABUS 
commands. The 
ABUS-VC3 provides the following function:
Volume Up/Down
Input Selection Up/Down
Room Off
System Off
Infrared repeating
Status indication
Infrared talkback
Volume level change identifi
cation
IR Remote Control ABO-41RC
The ABO-41RC 
Remote Control 
is a 
very flexible 
device; it 
has been 
designed for 
easy operation 
and to 
allow users 
to tailor 
the operation 
for more 
sophisticated operation. 
It includes 
a code 
library for 
easy 
selection of 
codes, a 
dedicated ABUS 
code bank, 
all buttons 
can learn 
commands (including 
bank buttons) 
all buttons 
can learn 
macros (in
-
cluding the bank buttons).
Quite often 
there are 
products not 
listed in 
the library 
so it 
is possible 
to encode 
commands into 
the Remote 
Control from 
the ones 
supplied 
with the 
source components. 
It is 
also possible 
to encode 
multiple 
commands into 
one key 
(macros). For 
example; you 
could encode 
into 
the SA
T bank 
button commands 
to turn 
on your 
television monitor, the 
cable box 
and select 
the audio 
input in 
the ABUS 
Multi-Source Multi-
Zone hub. 
The operator 
will then 
only need 
to press 
one button 
to turn 
the system 
on and 
set it 
up for 
normal TV 
operation. Additional 
ABO-
41RC can be purchased if required.
Note: Macro 
strings take 
time to 
emit, the 
operator should 
take care 
not to 
turn the 
re-
mote control 
away from 
the infrared 
receiver on 
the Volume 
Control Module 
or speaker 
before all commands have been generated.
ABUS Compatibility
This product 
complies with 
the A-BUS 
format. The 
A-BUS format 
has been 
adopted by 
other manufacturers 
who make 
variety of 
products that 
can give 
your system 
added 
flexibility. When 
looking to 
expand and/or 
upgrade your 
home entertainment 
system, 
be sure to look for products that carry the A-BUS trademark.
 
Compar
iso
no
fa
nA
-B
US™
Inp
uta
gai
nst
as
tan
dar
dR
J-4
5S
ock
et
RJ-
45
Soc
ket
Soc
ket
8
7
5
3
1
6
4
2
8
7
6
5
4
3
2
1
Pin
Sig
nal
Fun
ctio
n
NC
Not
Con
nec
ted
Bro
wn
Bro
wn
&W
hite
Blu
e&
White
Green&
White
Green
Orange
&W
hite
Orange
Blu
e
NC
Not
Con
nec
ted
NC
Not
Con
nec
ted
NC
Not
Con
nec
ted
RX-
Rec
eiv
e-v
e
RX+
Rec
eiv
e+
ve
TX-
Transmi
t-ve
TX+
Transmi
t+
ve
8
7
5
3
1
6
4
2
8
7
6
5
4
3
2
1
Pin
Sig
nal
Fun
ctio
n
24v
24v
+ve
GN
D
Gro
und
GN
D
Gro
und
GN
D
Gro
und
STA
T
Sta
tus
SIG
Sig
nal
RC
H
Rig
htC
han
nel
LC
H
Lef
tC
han
nel
RJ4
5E
thernet
vs.
Page 2
Page 5