Clarke IG1000 작동 가이드

다운로드
페이지 28
9
CHECKING THE ENGINE OIL LEVEL
NOTE: Place the generator on a level surface and check the oil level as 
follows.
1. Remove the left side maintenance panel.
2. Turn the oil filler cap anti-
clockwise and remove from the oil 
reservoir, wipe the dipstick with a 
clean cloth.
3. Insert the dipstick back into the oil 
filler tube and then remove it 
again. Do not screw in the oil filler 
cap/dipstick when doing this.
4.
Max Level
Min. Level
If the oil is below the Min. level on 
the dipstick, add oil to the oil 
reservoir.
• Oil Capacity (See 
“Specifications” on page 23)
• We recommend the use of 
SAE30 oil in this generator.
• Do not tilt the generator when 
adding engine oil. This could 
result in overfilling and damage 
to the engine.
5. Replace the oil filler cap.
WARNING: TO CARRY OUT THIS CHECK, SWITCH THE ENGINE OFF. 
WARNING: TAKE CARE NOT TO TOUCH ANY HOT PARTS OF THE 
GENERATOR WHEN CHECKING THE OIL LEVEL.