2. Attach the other end of the 50-pin feeder cable to the Champ connector 
on the 10Base-T compliant ethernet device.
3. Check that the link LED on the 10Base-T ethernet device and the 
applicable 
 
TPLNK
 
 LED on the EMC38-12 are on. If the LEDs are not 
on, perform each of the following steps until the LEDs are on:
a.
Check that the 10Base-T device and the EMC38-12 have power.
b. Verify the cabling between the EMC38-12 and the 10Base-T 
device.
c.
Check the cable for continuity.
If a link has not been established, contact Cabletron Systems Technical 
Support.
 
3.2
CONNECTING A FIBER OPTIC LINK SEGMENT
 
When connecting a fiber optic link segment the EMC38-12 keep the 
following in mind:
ST connectors attach to ST ports much like BNC connectors attach 
to BNC ports. Insert the connector into the port with the alignment 
key on the connector inserted into the alignment slot on the port. The 
connector is then turned to lock it down. 
The physical communication link consists of two strands of fiber 
optic cabling: the Transmit (TX) and the Receive (RX). The 
Transmit strand from the applicable port on the module will be 
connected to the Receive port of a fiber optic ethernet device at the 
other end of the segment. For example, TX of the applicable port on 
the module will go to RX of the other fiber optic device. The Receive 
strand of the applicable port on the module will be connected to the 
Transmit port of the fiber optic ethernet device. For example, RX of 
the applicable port on the module will go to TX of the other fiber 
optic device.