APPENDIX A
CABLE REQUIREMENTS
This appendix provides cable requirements for each of the EMC38-12 
ports.
A.1
10Base-T TWISTED PAIR REQUIREMENTS
When you connect a 10Base-T twisted pair segment to the EMC38-12, 
the device at the other end of the twisted pair segment must meet IEEE 
802.3 10Base-T specifications. Your 10Base-T twisted pair segment must 
meet the following requirements.
Segment Length
The IEEE 802.3 10Base-T standard requires that 10Base-T devices must 
be able to transmit from 0 to at least 100 meters (328 feet) per segment of 
24-gauge unshielded twisted pair (UTP) cable.
Insertion Loss
The maximum insertion loss allowed for a 10Base-T segment is 11.5 db 
at all frequencies between 5.0 and 10.0 MHz. This includes the 
attenuation of the cable, connectors, and patch panel.
Impedance
10Base-T specifies cable impedance between 85 and 110 ohms.