Advantech Modem ADAM-4550 사용자 설명서
22
ADAM-4550 User's Manual
4.2 Read Configuration
Description Requests to read the current
baud rate and address from the
module.
module.
Syntax
$AA2(cr)
AA:
module address ( 2 hexa-
decimal characters )
Response
!AATTCCFFPP(cr) if the com-
mand is valid (refer to “Set New
Configuration” in Command Set)
mand is valid (refer to “Set New
Configuration” in Command Set)
?AA(cr) if an invalid command is
entered
entered
Example
Command :
$0A2(cr)
Response:
!0A40AA2103(cr)
!0A40AA2103(cr)
4.3 Write Identification
Description Requests to assign identification
data to the module at address
AA. The identification character
lengths can range from 0 to 16
bytes including carriage-return.
AA. The identification character
lengths can range from 0 to 16
bytes including carriage-return.
Syntax
$AA6(identification
characters)(cr)
characters)(cr)
Response
!AA(cr) if the command is valid
?AA(cr) if an invalid command is
entered
entered
Example
Command:
$0A6ADAM4550 Unit#1(cr)
$0A6ADAM4550 Unit#1(cr)
Response:
!0A(cr)