Table 4 - Read Command Format 
READ – Displays the current parameter setting  
 
Command Entry Format  
READ <Parameter Name><CR> 
System Response for Valid Command  
READ <Parameter Name> <Parameter Value><CR>> 
System Response for an Invalid Command  
<CR>? 
Sample Entry  
System Response  
READ IP Address<CR> 
READ IP Address 192.168.0.10<CR>> 
2020.3.3.5 SLOT 
Command 
The SLOT command is required to permit accessing functional modules in the system.  After 
issuing this command the user gains access to the functions of the module contained in the 
designated card slot.   
Table 5 - The SLOT Command 
SLOT – Accesses a selected module by its Slot number in the system 
Command Entry Format  
SLOT=<number><CR> 
System Response for Valid Command  
><System Prompt> 
System Response for an Invalid Command  
<CR>? 
Sample Entry  
System Response  
SLOT=3 
>     [The user programs the module in slot 3] 
2020.3.3.6 Programming 
Example 
A typical example to control a MUX9 module located as slot 3 in the chassis is as follows: 
>slot=3 
>set c1id=023 
>set c2id=024 
2020.3.3.7 HELP 
Command 
The HELP command is used to gain insight into the remote instructions associated with a 
specific module.  The command format and acceptable parameter value(s) are returned.  The 
HELP command is issued after selecting a module using the SLOT command.  The ETHCX1 