Dimplex Shower 사용자 설명서

다운로드
페이지 6
2)  Switch on the electrical supply at the 
double pole isolating switch, the power 
neon on this switch should light.
3)  Start the shower by pressing the ‘Cold’
power selector button. Water should 
start to flow from the handset within a 
few seconds. The water will be at full 
force and will run cold.
4) Now press the ‘Low’ power selector 
button. Allow a few seconds for the 
warmer temperature to reach the 
showerhead – this shows that the ‘Low’
power is operating correctly.
5) Now press the ‘High’ power selector 
button. The temperature at the shower
head will rise further – this shows that 
the full power setting is operating 
correctly.
6) Turn the bottom temperature control 
knob clockwise for hotter water and 
anti-clockwise for cooler water. Allow 
a few seconds between selections for 
the temperature change to reach the 
showerhead. Note that selecting a 
hotter setting in the temperature 
control reduces the flow of water.
7) Press the STOP button to stop the water 
flow. Water should continue to flow, 
eventually running cool before 
switching off.
A small amount of water may continue to
drip from the unit as water drains from the
pipe-work. This should stop within a few
minutes.
The commissioning procedure is now 
complete.
SECTION 4 
Operation
‘Power indicator’:
The power indicator on the shower unit 
will light when the shower is switched 
on and water is flowing on one of the 
two heat settings. The indicator does 
not light on the cold setting.
‘Auto Reset Indicator’
The Auto Reset Indicator will illuminate if
an overheat temperature is sensed
during operation. Once activated the
electricity supply to the elements is
switched off until the unit has cooled
sufficiently, where upon power to the
elements will be restored. 
‘Low Pressure Indicator’
The low pressure indicator will 
illuminate if the mains water supply
pressure falls below the minimum 
level. The heat settings will be 
disabled until normal operating 
pressure is restored.  
1) Switch on using the pull-cord or wall 
mounted switch.  
2)  To start the shower, turn the temperature
dial to the desired number and press 
the desired power button, upon which 
water will start to run through the 
shower.
3) The shower has three positions 
‘Cold’, ‘Low’ power and ‘High’ power.
‘Cold’ setting:
Adjustment of the flow control on this 
setting will only alter the flow of water 
not the temperature.
FINAL ASSEMBLY AND COMMISSIONING / OPERATION
OPERATION / LOOKING AFTER YOUR SHOWER
‘Low’ setting:
This is the low power setting for economy
during warmer months or when a 
cool shower is required.
‘High’ setting:
This is the full power setting. 
4) If necessary turn the bottom ‘temperature’
control knob slowly to obtain the desired
showering temperature. Waiting a few 
seconds after each adjustment for the 
temperature to stabilise.
To increase the shower temperature
Turn the temperature control knob 
clockwise, this will decrease the flow 
of water and increase the shower 
temperature.
To decrease the shower temperature
Turn the temperature control knob 
anti-clockwise, this will increase the flow
of water and decrease the shower 
temperature.  
5)  To stop the shower press the STOP button.
Allow the water to run until it stops 
automatically 
6) Switch off the electricity supply using 
the pull-cord or wall mounted switch.  
SECTION 5
Looking after your shower
The showerhead should be cleaned 
periodically to remove limescale or other
particles which will reduce the performance
of the shower. The frequency of cleaning
will vary according to the local water 
quality. In hard water areas cleaning will
be needed more often than in soft water
areas. A liquid non-abrasive bathroom
HIGH
LOW
COLD
LOW
PRESSURE
AUTO
RESET
TEMPERATURE
STOP
Cooler
Warmer
TEMPERATURE
TEMPERATURE
HIGH
LOW
COLD
LOW
PRESSURE
AUTO
RESET
STOP
8
9
Dimp13292-Shower inst aX4  5/5/04  2:08 pm  Page 9