STOPPING THE GENERATOR 
 
To stop this generator: 
1. Turn off all connected electrical devices and then unplug them. 
2. Switch the circuit breaker to the “off” position. 
3. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator. 
4. Set the engine switch to the “off” position. 
5. Turn the fuel valve to the “off” position. 
 
                                                                                
   
Allow this generator to cool down before touching areas that become hot during operation. 
 
                                                                                
 
Allowing gasoline to sit in this generator's fuel tank for extended time without use can increase the difficulty in starting this generator in 
the future. Never store this generator for extended time with gasoline in the fuel tank. 
 
 
 
 
 
 
MAINTENANCE/CARE 
 
Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator 
as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 10. 
 
STOP! 
If you have questions about any maintenance procedures described in this manual, call 1-866-460-9437 , Monday - Friday, 8 AM - 4 PM Central 
Time.
 
 
                                                                                
 
Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance 
procedures. Keep heat, sparks and flame away.
 
 
                                                                                
 
Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause 
death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual. 
 
Recommended Maintenance Schedule 
 
 
 
Each Use 
Every Month or 
Each 20 Hrs 
Every 3 Months or 
Each 50 Hrs 
Every 6 Months or 
Each 100 Hrs 
Every Year or 
Each 300 Hrs 
Engine Oil 
Check Level 
 
 
 
 
 Replace  
 
 
 
Air Filter 
Check 
 
 
 
 
 Clean     
 
 
Fuel Filler Cap 
Clean 
 
 
 
 
Spark Plug 
Check/Clean 
 
 
 
 
Fuel Tank 
Verify Gas Level 
 
 
 
 
 Clean      
  
Figure 10 - Recommended maintenance schedule 
 
 
 
Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator 