NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Ne pas se servir de cet appareil s'il a été plongé 
dans l'eau, complètement ou en partie.  Appeler 
un technicien qualifi é pour inspecter l'appareil et 
remplacer toute partie du système de contrôle et 
toute commande qui ont été plongés dans l'leau. 
Test gauge  connections are provided on the front 
of the millivolt gas control valve (identifi ed OUT 
for the manifold side and IN for inlet pressure.  A 
1/8" NPT test gauge connection is provided on the 
electronic gas control valve adjacent to the outlet 
to the main burner.  
Minimum inlet gas pressure to these appliances is 
5.0  inches water column (1.24 kPa) for natural gas 
and 11 inches water column (2.74 kPa) for propane 
for the purpose of input adjustment.
Maximum inlet gas supply pressure to these appli-
ances is 10.5 inches water column (2.61 kPa) for 
natural gas and 13.0 inches water column (3.23 
kPa) for propane.
The appliance must be isolated from the gas supply 
piping system (by closing its individual manual 
shut-off valve) during any pressure testing of the 
gas supply piping system at test pressures equal 
to or less than 1/2 psig (3.5 kPa).
The appliance and its individual shut-off valve 
must be disconnected from the gas supply piping 
system during any pressure testing of that system 
at pressures in excess of 1/2 psig (3.5 kPa).
These appliances must not be connected to a 
chimney or fl ue serving a separate solid fuel 
burning appliance.
Any safety guard or screen removed for servicing 
the appliance must be replaced prior to operating 
the appliance.
Carbon Monoxide Poisoning: Early signs of 
carbon monoxide poisoning are similar to the fl u 
with headaches, dizziness and/or nausea. If you 
have these signs, obtain fresh air immediately. 
Turn off the gas supply to the appliance and have 
it serviced by a qualifi ed professional, as it may 
not be operating correctly.
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled through a 
remotely located optional wall switch. Separate 
switches may provide independent control for 
the remote controlled fi replace operation (op-
tional equipment).  
In lieu of remote or remote wall switch operation, 
the appliance must be operated directly through 
the controls located on the front of the valve 
located within the control compartment which is 
located behind the control compartment access 
panel below the appliance front glass enclosure 
panel. See Figure 1.
Gas Controls/Control Compartment 
Access
The gas controls can be found behind the control 
compartment access panel.  To open the control 
compartment access panel, actuate the spring 
loaded magnetic catches securing the panel.  
First, gently depress the upper right top corner 
of the panel until the magnet catch "pops" the 
door free.  Then, gently pulling the panel forward, 
disengage the left magnet catch and allow the 
panel to swing down to open.  
Operation of millivolt and electronic gas control 
systems are different.  Before lighting and op-
erating your appliance determine if you have a 
millivolt or electronic appliance. See Figure 1 
for access to the control compartment.  
Millivolt appliances will be fi tted with the gas 
control valve shown in Figure 3 on Page 4.
Appliances with electronic systems will be fi t-
ted with the electronic valve shown in Figure 
2 on Page 4
. 
Familiarize yourself with the gas control valve 
that your appliance uses.
Millivolt Appliances -
To light millivolt appliances refer to the detailed 
lighting instructions found on Page 18 (English
and Page 19
  (French).  Millivolt appliance 
lighting instructions may also be found on the 
pull-out lighting instruction labels attached to 
the gas control valve
.  Refer to Figure 3 on Page 
 for the  location of the piezo Igniter.
Millivolt appliances may be fi tted with an optional 
burner ON/OFF Rocker Switch. The optional ON/
OFF Rocker switch will be installed in the bracket 
just beneath the gas control valve. Once the pilot 
is lit, the ON/OFF rocker switch will control the 
appliance ON/OFF operation. To operate:  Toggle 
the switch between its ON and OFF positions.
Figure 1
Piezo Igniter
Millivolt
Gas Valve
Control
Compartment
Access Panel
       
WARNING
B-Vent appliances are not designed 
to operate in negatively pressured 
environments (pressure within the 
home is less than pressures outside). 
Significant negatively pressured 
environments caused by weather, 
home design, or other devices may 
impact the operation of these appli-
ances.  Negative pressures may result 
in poor fl ame appearance, sooting, 
damage to property and/or severe 
personal injury. Do not operate these 
appliances in negatively pressured 
environments.
       
WARNING
Failure to comply with the installa-
tion and operating instructions pro-
vided in this document will result in 
an improperly installed and operat-
ing appliance, voiding its warranty.  
Any change to this appliance and/or 
its operating controls is dangerous.  
Improper installation or use of this 
appliance can cause serious injury 
or death form fi re, burns, explosion 
or carbon monoxide poisoning.
       
WARNING
Children and adults should be 
alerted to the hazards of high sur-
face temperatures. Use caution 
around the appliance to avoid burns 
or clothing ignition. Young children 
should be carefully supervised 
when they are in the same room 
as the appliance.
       
AVERTISSEMENT
Surveiller les enfants.  Garder les 
vêtements, les meubles, l'essence 
ou autres liquides à  vapeur infl am-
mables lin de l'appareil.
       
WARNING
Do not place clothing or other fl am-
mable materials on or near this 
appliance.