Brother MD-611 사용자 매뉴얼

다운로드
페이지 84
11. TABLE OF ERROR CODES 
 
BAS-300G, BAS-311G, BAS-326G 
67 
11. TABLE OF ERROR CODES 
    DANGER 
Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet before 
opening the cover of the control box. Touching areas where high voltages are present can result in severe injury.
 
 
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display window. 
Follow the remedy procedure to eliminate the cause of the problem. 
Switch-related errors 
Code 
Cause and remedy 
E010 
Stop switch was pressed. Press the RESET key to clear the error. 
E011 
Stop switch was pressed. Press the RESET key to clear the error. 
Press the   key to move the feed mechanism so that you can continue sewing. 
E015 
The stop switch was still being pressed, or there is a problem with the stop switch connection. 
Turn off the power, and then check that connector P13 on the main PCB is properly connected. 
E016 
Problem with the stop switch connection. 
Turn off the power, and then check that connector P13 on the main PCB is properly connected. 
E025 
Foot switch is depressed to the 2nd step.  
Turn off the power and check the foot switch. 
(If using a two-pedal foot switch, the power was turned on while the start switch was still depressed, or the start 
switch was pressed without the work clamp being lowered.) 
If the power has been turned on while the start switch was still depressed, turn off the power and check the start 
switch. 
If the start switch was depressed without lowering the work clamp, depress the work clamp switch to lower the work 
clamp. 
E035 
Foot switch is depressed to the 1st step. (Work clamp switch if using a two-pedal foot switch) 
Turn off the power and check the foot switch. 
E036 
A foot switch that does not match specifications is connected, or work clamp mode has not been set correctly. 
Use a foot switch that matches specifications, or initialize the memory switch settings. 
E050 
Machine head tilting was detected after the power was turned on. 
Turn off the power, and then return the machine head to its original position. 
Check that connector P9 on the main PCB is properly connected. 
E051 
Machine head tilting was detected while the sewing machine was operating. 
Turn off the power, and then check that connector P9 on the main PCB is properly connected. 
E055 
Machine head tilting was detected when the power was turned on. 
Turn off the power, and then return the machine head to its original position. 
Check that connector P9 on the main PCB is properly connected. 
E065 
An operation panel key was still being pressed when the power was turned on, or key is faulty. 
Turn off the power and check the operation panel.