Installation continued-
 
 
 
 
 
 
 
 
 
 
 
                                           Figure 1 
 
 
 
 
 
 
 
 
 
 
 
Combustion Air Supply 
 
 
All combustion air must be supplied from outdoors by one of the following 
installation methods and as illustrated in Figure 2.  The flow of combustion and 
ventilating air must not be obstructed.  Adequate air must be supplied for 
combustion and ventilation.  An insufficient supply of air will cause recirculation 
of combustion products resulting in air contamination that may be hazardous to 
life.  Such a condition often will result in a yellow, luminous burner flame, 
causing carboning or sooting of the combustion chamber, burners and flue 
tubes with possible damage to the heater. 
 
AIR INTAKE INSTALLATION - 3” (7.6cm) diameter telescoping air intake and 
leg enclosure are required to supply fresh air to the water heater for 
combustion (kit P/N 239-37025-01 for 30 gallon (113.5L) water heaters and 
239-37025-02 for 40 gallon (151.4L) water heaters. Note:  When a mobile 
home is tightly skirted, an air inlet opening in the skirting must be 
provided.  The opening shall have a minimum free area of at least 9 in
(22.9cm
2
).  If the opening is screened or covered with a louver, the total 
free area must be at least 9 in
2
 (22.9cm
2
)The following steps must be  
followed for proper installation of these air supply components:  
(Refer to Figure 2).  
IMPORTANT
 
The flow of combustion and ventilating air must not be obstructed. 
Minimum Clearances From 
Combustible Materials 
 
A 0” 
(0cm) 
B 0” 
(0cm) 
C 3” 
(7.62cm) 
78” (1.98mm)  
VENT ----