Weber FLAME 사용자 매뉴얼

다운로드
페이지 20
20
MAINTENANCE
MAIN BURNER FLAME PATTERN
The Weber
®
 gas fi replace burner has been factory set for the correct air and 
gas mixture. A correct fl ame pattern is: 
 
• A yellow to light-orange fl ame 
An incorrect fl ame pattern is:
 
• A dark orange fl ame
 
• Smoke-producing fl ame 
If the fl ames appear to be darker orange throughout the burner, sooting 
occurs, or smoke is produced; follow the burner and spider screen cleaning 
procedures.
IGNITION SYSTEM
If the Ignition System fails to ignite the burner, light manually. If Manual igni-
tion is successful, then check the Ignition System.
• 
Check that both the white (2) and black (3) ignition wires are attached 
properly.
• 
Check that the igniter button pushes in completely and returns.
• 
Check to see if the igniter is loose in the frame. Tighten if necessary.
If the Ignition System still fails to ignite the burner, see Manual Lighting pro-
cedure and contact your dealer.
(2)
(3)