Waves SSL 4000 E 사용자 설명서

다운로드
페이지 7
  
  
  
Dynamics Sections Controls (top to bottom)  
 
1. Compressor (white knobs)  
 
a. The compressor’s Ratio/Slope can be set from 1 to infinity (limiter).  
 b. 
The 
Threshold is variably adjustable from +10 dB to -20 dB.  
 
c. When the Attack time switch is set to Slow (F.ATK off,) attack time is auto-
sensing and program dependent.  In the Fast setting (F.ATK,) attack time will be 
forced to 1 ms.  
 
d. Release time is adjustable from 0.1 sec to 4 seconds.  
 
2. Expander/Gate (green knobs)  
 
a. The expander’s Threshold is variable from -30 dB to +10 dB  
 b. 
Range is variable from 0 – 40 dB.  
 
c. When the Attack time switch is set to Slow (F.ATK off,) attack time is auto-
sensing and program dependent.  In the Fast setting (F.ATK,) attack time is 1 ms.  
 d. 
Release time is adjustable from 0.1 sec to 4 seconds.  
 e. 
The GATE switch toggles the section from an expander (default mode) into a 
gate.