b. Calculate the desired counts for a basket speed of 24 RPMs:
C
d
 = [RPM
d
 * (C/RPM)] + D
C
d
 = [24 RPMs * (6 counts per RPM)] + 15
159 = 144 + 15
c. Calculate the desired voltage:
V
d
 = C
d
 / 409.5
0.3883 = 159 / 409.5
2. The DC voltage measured at the output terminals of the D-to-A board and at analog voltage
input terminals FV and FC on the inverter (shown in Figure 2) should match this number.
You may see a small voltage drop from the D-to-A board to the inverter.
Figure 2: Measuring Control Voltage at D-to-A Board and Inverter
Digital-to-Analog Board
Legend
A.
 MTA-43 Pin 3
B.
 MTA-43 Pin 8
C.
 Inverter terminal A1
D.
 Inverter terminal AC
E.
 Inverter terminal FV
F.
 Inverter terminal FC
Inverter Analog Terminals for Yaskawa F7
Inverter Analog Terminals for Yaskawa GPD 506
.
3. If this value is wrong at the D-to-A board, replace the board.