Mitsubishi Electronics Mitsubishi Programmable Logic Controller QD75P 사용자 설명서

다운로드
페이지 768
5 - 20
MELSEC-Q
5   DATA USED FOR POSITIONING CONTROL
5.2 List of parameters
5.2.1 Basic parameters 1
Setting value, setting range
Setting value buffer memory
address
Item
Value set with peripheral device
Value set with sequence
program
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
0 : mm
0
1 : inch
1
2 : degree
2
Pr.1 Unit setting
3 : pulse
3
3
0
150
300
450
Pr.2
No. of pulses per
rotation (Ap)
(Unit : pulse)
1 to 65535
1 to 65535
1 to 32767
  :Set as a decimal
32768 to 65535
  :Convert into hexadecimal
   and set
20000
1
151
301
451
Pr.3
Movement amount per
rotation (Al)
The setting value range differs according to the " Pr.1  Unit
setting".
Here, the value within the [Table 1] range is set.
 
 [Table 1] on right page
20000
2
152
302
452
1 : 1-fold
1
10 : 10-fold
10
100 : 100-fold
100
M
o
v
e
m
ent
 a
m
ount
 per pul
s
e
Pr.4
Unit magnification (Am)
1000 : 1000-fold
1000
1
3
153
303
453
Pr.1
Unit setting
Set the unit used for defining positioning operations. Choose from the following
units depending on the type of the control target:  mm, inch, degree, or pulse.
Different units can be defined for different axes (axis 1 to 4).
(Example) Different units (mm, inch, degree, and pulse) are applicable to different
systems:
mm or inch..... X-Y table, conveyor (Select mm or inch depending on the
machine specifications.)
degree ........... Rotating body (360 degrees/rotation)
pulse .............. X-Y table, conveyor
 When you change the unit, note that the values of other parameters and data
will not be changed automatically.
After changing the unit, check if the parameter and data values are within the
allowable range.
Set "degree" to exercise speed-position switching control (ABS mode).