Meco Electric Water Cooler 사용자 설명서

다운로드
페이지 6
- 3 - 
 
ALL RIGHTS RESERVED © MECO 2003 
 
Installation Instructions 
1)  To facilitate proper air circulation, the cooler should not be installed in any enclosed 
or confined space.  
2)  Prior to installation, remove back cover of cooler and visually inspect for transit 
damage. Temporarily connect cooler to electric supply and switch on the thermostat. 
Check that fan is operating and not jammed.  
3)  For installation, connect the water inlet and wastewater drain connections. Do not 
use excessive force on the brass inlet and drain connectors of the cooler, as this 
tends to damage it.  
4)  Connect 3-pin 15-ampere plug to the cooler's main power cable with the green or 
yellow wire connected to the earthing terminal of the plug.  
5)  Always use a proper circuit breaker to avoid compressor burnout.  
Automatic voltage stabilizer should be used in low voltage areas. 
Specifications 
Cabinet 
Made of heavy gauge vinyl-coated and stainless steel sheets, in various pleasing 
colours. Drain pot made of hard plastic, or stainless steel. Back panel easily removable 
for cleaning and servicing. Top cover of plastic (except model 100P). Base of plastic / 
stainless. 
Refrigeration System  
Fitted with world renowned, high starting torque, high temperature compressors. 
Condenser and fan are slightly oversized to ensure efficient working in high 
temperatures. Copper cooling coil metal bonded to outside of water tank. Whole system 
hermetically sealed with R-22 (or R-12) as refrigerant.  
Water System  
All copper / brass water system. Water tank made of heavy gauge copper sheet tinned 
from inside. Tank safety tested at 10 kg/cm
2
 (142 p.s.i.) with recommended maximum 
working pressure of 5 kg/cm
2
 (71 p.s.i.). Fitted with high quality chrome plated brass 
taps.  
Insulation  
Moisture proof and highly effective polyurethane or polystyrene insulation.