Thermador PR305PH 지침 매뉴얼

다운로드
페이지 11
English 3
6. For Natural Gas ranges, note the original position of 
the slot in the valve screw. This can be done by 
engaging the screwdriver’s blade in the screw slot and 
marking the screwdriver’s handle to indicate the 
starting position of the valve screw. With the 
screwdriver still engaged, carefully rotate the valve 
screw counter-clockwise (CCW) 1/4 turn (or 90 
degrees) from its original position. Repeat this 
procedure to adjust the setting for each valve screw.
For LP Gas ranges or an appliance that has been 
converted to LP Gas, 
adjustment is rarely necessary. 
7. Turn on the gas and electrical power to the appliance. 
Reevaluate the flames. Repeat Steps 1 through 6 if 
further adjustment is necessary.