Installation - 
Mounting Height & Clearance
DUCTING
MIN. 22”  MAX 30”
net width
Minimum mount height between range top to hood bot-
tom should be no less than 22".
Maximum mount height should be no higher than 30".
It is important to install the hood at the proper mounting
height. Hoods mounted too low could result in heat
damage and fire hazard; while hoods mounted too high
will be hard to reach and will loose its performance and
efficiency.
If available, also refer to range manufacturer's height 
clearance requirements and recommended hood 
mounting height above range. Always check your local
codes for any differences.
A minimum 3-1/4 x 10"rectangular duct 
must be used to maintain maximum air 
flow efficiency.
Always use rigid type metal ducts only.
Flexible ducts could restrict air flow by up 
to 50%.
Use calculation worksheet to compute total
duct work.
ALWAYS, when possible, reduce the number 
or transitions and turns. If a reducer is used,
install a long reducer instead of a pancake
reducer. Reduce duct size as far away from
opening as possible.
If turns or transitions are required:
Install as far away from opening and as far
apart, between 2, as possible.
Minimum Duct Size:
Rectangular- 3-1/4 x 10” minimum 
(rear or top) 
Call Out Size                            Net Width
24”
23 3/4”
30”
29 3/4”
36”
35 3/4”
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage
before installation.
• If the unit is damaged in shipment, return
the unit to the store in which it was bought 
for repair or replacement.
• If the unit is damaged by the customer
repair or replacement is the responsibility 
of the customer.
• If the unit is damaged by the installer (if 
other than the customer), repair of replace
ment must be made by arrangement 
between customer and installer.