ELECTRICAL CONNECTION 
•  Remove the cover from the Field Wiring Compartment with a 
phillips screwdriver. 
•  Feed the Power Supply Cable through the electrical knockout. 
Connect the Power Supply Cable to the range- hood cable.  At-
tach the Power Supply Cable grounding lead to the green screw 
provided. Attach the White lead of the power supply to the 
White lead of the rangehood with a twist-on type wire connec-
tor. Attach the Black lead of the power supply to the Black 
lead of the rangehood with a twist-on type wire connector. 
•  Replace the cover. 
Chimney assembly 
Upper exhaust chimney
•  Slightly widen the two sides of the upper flue and hook them 
behind the brackets 7.2.1, making sure that they are well 
seated. 
•  Secure the sides to the brackets using the 4 screws 12c sup-
plied. 
Lower exhaust chimney
•  Slightly widen the two sides of the flue and hook them be-
tween the upper flue and the wall, making sure that they are 
well seated. 
•  Fix the lower part laterally to the hood body using the 2 screws 
12c supplied. 
•  On the recirculation version, fit the directional grids 8a – 8b in 
their housings making sure that the directional symbols are to-
wards the top and front of the hood. Also make sure that they 
are correctly inserted in the connection extension pieces 14.1.
12c
8a
2.1
2.2
2
8b
7.2.1
12c
Power supply cable
Green
Ground
screw