Direct Wire
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire) 
and be:
 
Flexible armored cable or nonmetallic sheathed copper cable 
(with ground wire), covered with flexible metallic conduit.  
All current-carrying wires must be insulated.
 
10-gauge solid copper wire (do not use aluminum).
 
At least 5 ft. (1.52 m) long.
ELECTRIC DRYER INSTALLATION REQUIREMENTS
Electrical Requirements – Canada only
It is your responsibility:
 
To contact a qualified electrical installer.
 
 To be sure that the electrical connection is adequate and in 
conformance with the Canadian Electrical Code, C22.1 – latest 
edition and all local codes. A copy of the above codes standard 
may be obtained from: Canadian Standards Association, 
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
 
To supply the required 4 wire, single phase, 120/240 volt,  
60 Hz., AC only electrical supply on a separate 30-amp circuit, 
fused on both sides of the line. A time-delay fuse or circuit 
breaker is recommended. Connect to an individual branch 
circuit.
 
This dryer is equipped with a CSA International 
Certified Power Cord intended to be plugged 
into a standard 14-30R wall receptacle. The cord 
is 5 ft (1.52 m) in length. Be sure wall receptacle 
is within reach of dryer’s final location.
 
 Do not use an extension cord.
 If you are using a replacement power supply cord, it is 
recommended that you use Power Supply Cord Replacement 
Part Number 9831317. For further information, please reference 
the service numbers located in the “Assistance or Service” 
section.
4-Wire 
Receptacle  
(14-30R)
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment- 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: 
Improper connection of the equipment- 
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with 
the dryer: if it will not fit the outlet, have a proper outlet 