Installation – 
Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 10” round duct must be used to 
PDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible 
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
$OVRXVHFDOFXODWLRQ RQSDJH WRFRPSXWHWRWDO
available duct run when using elbows, transitions 
and caps.
ALWAYS, when possible, reduce the number or 
transitions and turns. If long duct run is required, 
increase duct size. 
If turns or transitions are required; install as far 
away from hood duct output and as far apart, 
between the two as possible.
Minimum mount height between range top to hood 
bottom should be no less than 26”. 
Maximum mount height should be no higher than 
36”.
It is important to install the hood at the proper 
mounting height. Hoods mounted too low could 
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will 
ORVHLWVSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer range manufacturer’s height 
clearance requirements and recommended hood 
mounting height above range.
Vertical Ducting: 
10” round minimum
 
Horizontal Ducting:
N/A
DAMAGE-SHIPMENT / INSTALLATION:
‡ 3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
‡ ,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for 
repair or replacement.
‡ ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the 
customer.
‡ ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHU LIRWKHU
WKDQWKHFXVWRPHU UHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer 
and installer.
26” min.
36” max.
36”