Zephyr COKE36BRGX 매뉴얼

다운로드
페이지 10
5
Duct pieces
Total
Equivalent number
length x used     =
3-1/ 4” x 10”
Rect.,
straight
1 Ft.           x (     ) =
Ft.
7”-10” Round,
straight
1 Ft.           x (     ) =
Ft.
3-1/ 4” x 10”
Rect.90
0
elbow
15 Ft.          x (     ) =
Ft.
3-1/ 4” x 10”
Rect.45
0
elbow
9 Ft.           x (     ) =
Ft.
3-1/ 4” x 10”
Rect.90
0
flat elbow
24 Ft.          x (     ) =
Ft.
3-1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft.          x (     ) =
Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
5 Ft.           x (     ) =
Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
90
0
elbow
20 Ft.          x (     ) =
Ft.
6” Round,
90
0
elbow
15 Ft.          x (     ) =
Ft.
6” Round,
45
0
elbow
9 Ft.           x (     ) =
Ft.
Ft.
6” Round,
straight
1 Ft.           x (     ) =
Ft.
Subtotal column 1 =
Duct pieces
Total
Equivalent number
length x used     =
6” Round
wall cap
with damper
30 Ft.          x (     ) =
Ft.
Round
wall cap
with damper
30 Ft.          x (     ) =
Ft.
7” - 10” 
Round,
90
0
elbow
15 Ft.          x (     ) =
Ft.
7” - 10” 
7” - 10” 
Round,
45
0
elbow
9 Ft.           x (     ) =
Ft.
Ft.
Ft.
Ft.
6” Round,
roof cap
30 Ft.          x (     ) =
Ft.
7” - 10”
Round,
roof cap
30 Ft.          x (     ) =
Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork      =
6” round to
3-1/ 4” x 10”
rect.
transition
1 Ft.           x (     ) =
Ft.
6” round to
3-1/ 4” x 10”
rect.
transition
90
0
elbow
16 Ft.          x (     ) =
Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft.           x (     ) =
Ft.
7” round to
3-1/ 4” x 10”
rect.
transition
90
0
elbow
23 Ft.          x (     ) =
Ft.
Maximum Duct Length: 
For satisfactory 
air movement, the total duct length should 
not exceed 100 equivalent feet.
Installation – 
Ductwork Calculation Sheet