Speed Queen ADEE9B 설치 설명서

다운로드
페이지 24
8.   Using screwdriver, remove two door plugs, and reinstall on
opposite side of door opening.
DRY2503N_SVG
Figure 22
9.   Reinstall four hinge attaching screws, removed in Step 1.
D606I_SVG
Figure 23
 Wipe Out Inside of Dryer
Before using dryer for the first time, use an all-purpose clean-
er, or a detergent and water solution, and a damp cloth to re-
move shipping dust from inside dryer drum.
DRY2504N_SVG
Figure 24
 Plug In the Dryer
This appliance is to be supplied through a residual current device
(RCD) having a rated residual operating current not exceeding 30
mA.
 Electric Dryer
Connect the dryer to an electrical power source. Refer to Connect
Electrical Plug section for information on connecting power cord.
Connect to 30 Amp Circuit
D275I_SVG2
Figure 25
 Gas Dryer
Dryer requires 120 Volt, 60 Hertz electrical supply and comes
equipped with a 3-prong earth/ground plug. Refer to serial plate
for specific electrical requirements.
NOTE: The wiring diagram is located in the control cab-
inet.
WARNING
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and grounding MUST con-
form with the latest edition of the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1, and such local regulations as
might apply. It is the customer’s responsibility to
have the wiring and fuses installed by a qualified
electrician to make sure adequate electrical power is
available to the dryer.
W521
When plugging in the dryer:
• DO NOT overload circuits.
• DO NOT use an extension cord.
• DO NOT use an adapter.
• DO NOT operate other appliances on the same circuit. Use
separately fused 15 Amp circuits.
The dryer is designed to be operated on a separate branch, polar-
ized, three-wire, effective earth/ground, 120 Volt, 60 Hertz, AC
(alternating current) circuit protected by a 15 Ampere fuse,
equivalent fusetron or circuit breaker.
The three-prong earth/ground plug on the power cord should be
plugged directly into a polarized three-slot effective earth/ground
receptacle rated 120 Volts AC (alternating current) 15 Amps. Re-
Installation
  20
©
 Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
  Part No. 514320R1