TROUBLESHOOTING
PROBLEM
POTENTIAL CAUSE
CORRECTIVE ACTION
1 - Leaks from handle
2 - Insufficient flow rate
3 - Leak at connection points
4 - Loose faucet body
1.A - Cartridge unseated
1.B - Cartridge defective
1.B - Cartridge defective
2.A - Dirty aerator
2.B - Clog in supply hose / line
2.B - Clog in supply hose / line
3.A - Flexible hose leaking at connection point
3.B - Washer defective
3.B - Washer defective
4. - Mounting hardware became loose
3.A - Tighten hoses. If this does not resolve the issue, remove
the flexible hose and rethread, checking to make sure the
connection is secure. Make sure to use pipe tape.
the flexible hose and rethread, checking to make sure the
connection is secure. Make sure to use pipe tape.
2.B - Remove supply lines and flush lines.
2.A - Remove aerator and soak / clean with a non abrasive
agent (i.e. half hot water and half vinegar).
agent (i.e. half hot water and half vinegar).
1.B - Contact Vigo Technical Support for replacement.
1.A - Remove cartridge from housing, wash thoroughly with hot
water and reseat in housing.
3.B - Remove supply line and check the status of the washer. If
torn, washer must be replaced for a secure, non-leaking
connection.
torn, washer must be replaced for a secure, non-leaking
connection.
4. - From under the counter, use an adjustable wrench and
tighten the mounting hardware. Make sure the faucet is
perpendicular to the counter.
tighten the mounting hardware. Make sure the faucet is
perpendicular to the counter.
5 - Loose handle
5. - Set screw has become loose
5. - Take off hot/cold cover on handle. This will give you access
to the screw that connects the handle to the cartridge. Using
either an allen key or a flat head screw driver, tighten the screw
so handle has firm connection to cartridge.
to the screw that connects the handle to the cartridge. Using
either an allen key or a flat head screw driver, tighten the screw
so handle has firm connection to cartridge.
2.C - Clog in copper supply pins
2.C - Remove copper pins and flush/clean out.