IMPORTANT: Observe all governing codes and ordinances.
This installation must conform with all local codes and ordinances. 
In the absence of local codes, installation must conform with 
American National Standard, National Fuel Gas Code ANSI 
Z223.1/NFPA 54 or CAN/CSA B149.
A copy of the above code standards can be obtained from:
National Fire Protection Association 
One Batterymarch Park, Quincy, MA 02269
CSA International 
8501 East Pleasant Valley Road 
Cleveland, Ohio 44131-5575
The design of this dryer has been certified by CSA International 
for use at altitudes up to 10,000 feet (3048 m) above sea level at 
the B.T.U. rating indicated on the model/serial plate. Burner input 
adjustments are not required when the dryer is operated up to this 
elevation.
When installed above 10,000 feet (3048 m), a four percent (4%) 
reduction of the burner B.T.U. rating shown on the model/serial 
plate is required for each 1,000 foot (305 m) increase in elevation. 
For assistance when converting to other gas types and/or installing 
above 10,000 feet (3048 m) elevation, contact your local service 
company.
Gas Supply
GAS DRYER INSTALLATION REQUIREMENTS