5. Electrical Connection 
Before proceeding further, verify that the power supply is disconnected.  Verify 
that the appropriate electrical supply requirements have been met.  Please refer 
to the table on page 4 for appropriate electrical requirements.  The cooktop is 
supplied with a 48-inch long conduit for a connection to an accessible junction 
box.  The conduit consists of three insulated wires.  There are two hot lead 
conductors (black and red insulated-tinned copper) and one insulated ground 
conductor (green insulated-tinned copper). (See Wiring Diagram for model 
CR424 below
 
and on bottom of cooktop.)
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Wiring Diagram
 
Attach conductor wires to residence wiring in accordance with national, state and 
local electric codes. 
 
Warning 
– Grounding 
The entire appliance must be grounded at all times 
when the electrical power supply is on.  Do not 
ground the appliance with the neutral house supply 
wire (white).  A separate ground must be used. 
 
(4) @ 1200W = 4800W