COYOTE CSLX36NG 매뉴얼

다운로드
페이지 39
 
 
 
27 
Note: You will need to remove your cooking grates and 
flavorizers to see the electrodes. The electrodes should 
have a 1/8” to ¼” gap between the electrode and contact 
point.   
• 
Check your igniter battery and replace if needed. 
• 
Check for loose wire connections to the igniter or electrodes. 
• 
Check to see if debris is blocking the electrodes. 
• 
If the igniter is not working, can you light the grill with a lighter? 
Flare-ups
 
• 
Check flavorizers and cooking grates for excess food or 
grease build-up. 
• 
Ensure grill is not placed directly in the path of wind. 
Be sure drip tray is clean (do not use aluminum foil on drip 
tray.) 
Note: Some flare-ups may be inevitable if cooking greasy 
foods. 
Yellow Flames   
• 
Check the burner inlet for obstructions, particularly at air inlets 
for each burner. 
• 
Grill may be in an area that is too windy.
 
Flame  blows  out  on  low  setting 
or has uneven heat distribution. 
• 
Check  for  spider  webs  or  insect  nest  in  venturi  and  clean 
venturi. 
• 
Cold grill needs to be preheated for 5 minutes on high setting. 
• 
Venturi  may  be  misaligned  and  needs  to  be  lined  up  over 
orifices. 
• 
Cold  and  windy  weather  will  require  you  to  move  grill  away 
from the wind. 
• 
Lack of fuel. Check to see cylinder valve is open and cylinder 
has fuel.
 
Low  heat  with  the  knob  on 
“HIGH” 
• 
Check to see if the fuel hose is bent or kinked. 
• 
Make sure the grill area is clear of dust. 
• 
Check your gas supply and gas pressure.   
• 
If it is only one burner that appears low, make sure the orifice 
or burner is clean. 
Grill is Too Hot 
• 
Excess grease build-up causing grease fires. 
• 
Damaged or faulty regulator. 
Replace with factory authorized parts. 
• 
Cook on a lower temperature setting.
 
Flame  behind  control  panel  or 
control knob area. 
IMMEDIATELY shut off cylinder valve and allow grill to cool. 
• 
C
heck  for  spider  webs  or  insect  nest  in  venturi  and  clean 
venturi. 
• 
Gas  is  leaking  from  a  faulty  connection.  Tighten  connections 
with  an  adjustable  wrench  and  replace  damaged  parts. 
Perform a leak test on all connections before  cooking on grill 
again. 
• 
Venturi  may  be  misaligned  and  needs  to  be  lined  up  over 
orifice.
 
Fire at any connection. 
IMMEDIATELY shut off cylinder valve and allow grill to cool. 
• 
Gas  is  leaking  from  a  faulty  connection.  Tighten  connections 
with an adjustable wrench and replace damaged parts. 
• 
Perform a leak test on all connections before  cooking on grill 
again.