VENTING REQUIREMENTS
Because Whirlpool Corporation policy includes a continuous commitment to 
improve our products, we reserve the right to change materials and specifications 
without notice.
Dimensions are for planning purposes only. For complete details, see 
Installation Instructions packed with product. Specifications subject to 
change without notice.
Page 2 of 2
Rectangular to Round Transition:
Recommended Standard Fittings 
length. See the examples in “Recommended Vent Length.”
NOTE: The minimum 3" (7.6 cm) clearance must exist 
between the top of the microwave oven and the                        
rectangular to round transition piece so that the damper           
can open freely and fully.
27" (68.6 cm) models
A.   Roof cap
B.   6" (15.2 cm) min. diameter round vent
C.   Elbow (for wall venting only)
D.   Wall cap
E.   31⁄4" x 10" to 6" (8.3 x 25.4 cm to 15.2 cm)
     rectangular to round transition piece
F.   Vent extension piece, at least 3" (7.6 cm) high
A.   Rectangular to round transition piece: 31⁄4" x 10" to 6" = 5 ft
      (8.3 x 25.4 cm to 15.2 cm = 1.5 m)
B.   Roof cap: 31⁄4" x 10" = 24 ft (8.3 x 25.4 cm = 7.3 m)
C.   90° elbow: 3 " x 10" = 25 ft (8.3 x 25.4 cm = 7.6 m)
D.   90° elbow: 6" = 10 ft (15.2 cm = 3 m)
E.   Wall cap: 31⁄4" x 10" = 40 ft (8.3 x 25.4 cm = 12.2 m)
F.   45° elbow: 6" = 5 ft (15.2 cm = 1.5 m) 
G.  
Recommended Vent Length
A 3
1
4
" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round 
vent should be used.
The total length of the vent system including straight vent, 
elbow(s), transitions and wall or roof caps must not exceed 
the equivalent of 140 ft (42.7 m) for either type of vent. See 
“Recommended Standard Fittings” section for equivalent 
lengths.
For best performance, use no more than three 90° elbows.
To calculate the length of the system you need, add the 
equivalent lengths of each vent piece used in the system.           
See the following examples: 
3
1
4
" x 10" (8.3 x 25.4 cm) vent system = 73 ft 
(22.2 m) total
A.   One 3
¼
" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m)
B.   1 wall cap = 40 ft (12.2 m)
C.   2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
6" (15.2 cm) vent system = 73 ft (22.2 m) total
A.   Two 90° elbows = 20 ft (6.1 m)
B.   1 wall cap = 40 ft (12.2 m)
C.   1 rectangular to round transition piece = 5 ft (1.5 m)
D.   2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)
If the existing vent is round, a rectangular to round transition 
piece must be used. In addition, a rectangular 3" (7.6 cm) 
extension vent between the damper assembly and rectangular 
to round transition piece must be installed to keep the damper 
from sticking.
LOCATION REQUIREMENTS
Special Requirements 
For Wall Venting Installation Only:
• 
Cutout must be free of any obstructions so that the vent 
For Roof Venting Installation Only:
• 
If you are using a rectangular to round transition piece, 3" 
(7.6 cm) clearance needs to exist above the microwave 
oven so that the damper blade can open freely and fully. 
See “Rectangular to Round Transition” illustration in 
A
B
C
E
F
D
3" (7.6 cm)
A                                          B
C
6 ft (1.8 m)
2 ft
(0.6 m)
A                                                                  B
C                                  D
6 ft (1.8 m)
2 ft
(0.6 m)
A                           B                            C
D                  E                    F               G
Ref. W10724870A