1.  Mark a level line on the wall at 16” below bottom of hood. 
2.  Position the lower section of backsplash (flat part with flange on top) on the wall. 
     Center it side to side and mark the top and bottom holes. Remove the lower section from 
     the wall. 
3.  If installing onto drywall only and not onto studs, insert wall anchors (we recommend EZ  
     anchors) into the marked holes.  If installing onto studs, attach screws without EZ anchors. 
4.  Attach lower section of backsplash to wall with screws provided. 
5.  Position upper section of backsplash by engaging its flange with the lower section.  Push up
     to fully engage flanges*, center it side to side and mark the location of the mounting holes.
     Remove the upper section from drywall and install wall anchors into marked holes. 
5b.If hood is already installed, attach wall anchors into the (3) holes from inside the hood at the
     bottom.  These are the holes which the upper section will line up with and mount to the wall.  
6.  Insert retaining clips and hinge clips to the upper section.  The retaining clips go in the top 
      top two openings and the hinge clips go in the bottom four openings. (see diagram, page 4) 
      Fasten and tighten nuts to the clips on back of the upper section with the provided 
      hardware. 
7.  Attach upper section to wall with screws provided. If hood is already installed, Insert the top
      2” lip of the upper section behind the bottom of the hood and line up the holes with the (3) 
      holes at the bottom of the hood. Insert screws into holes and fasten upper section to wall. 
*note: in some installations, the flanges will not fully engage in the final install.  This is fine
 since the weight of the upper section will rest against the bottom section. 
4