Monogram ZV750SPSS 설치 설명서

다운로드
페이지 56
3
Design Information
MODELS AVAILABLE
Model ZV750, 360 CFM
Model ZV755, 500 CFM
These hoods may be installed to vent to the outdoors, 
or they may be installed for recirculating operation. 
All necessary parts for recirculating operation are
supplied with the hood. No kits required. 
• These vent hoods can be installed over any 30″ or 36″
Monogram electric or gas cooktop except Monogram
Professional cooktops or ranges larger than 30”. 
• Reversible duct covers accommodate recirculating
operation.
• The telescopic duct covers conceal the ductwork
running from the top of the hood to the ceiling.  
• The supplied duct cover is sized to reach ceiling heights
up to 9′ or more, depending on the installation. See the
table on page 8.
PRODUCT DIMENSIONS AND CLEARANCES
The vent hood must be installed 24″ minimum, and 
30
maximum above the cooking surface. 
NOTE: Installation height should be measured from
the cooking surface to the lowest part of the hood.
ZX7510SPSS Duct Cover Accessory
This accessory is available for installations with ceiling
heights above 9′ to 10′ and higher. See the table on
page 8.
The duct cover accessory must be on-site with the
hood at the time of installation.
*Height 
to Ceiling
8-1/4"
21-5/8”
34-5/8ļ (excluding utensil rods)
35-3/4ļ (including utensil rods)
CONTENTS
Models Available ................................................................................3
Product Dimensions..........................................................................3
Advance Planning
Ductwork Planning  ..........................................................................4
Wall Framing for Adequate Support  ......................................4
Advance Planning ............................................................................ 4
Installation Preparation 
Duct Fittings..........................................................................................5
Power Supply ......................................................................................6
Tools and Materials Required ......................................................6
Remove the Packaging  ..................................................................7
Check Installation Hardware  ......................................................7
Determine Installation Height......................................................8
Installation Instructions
Installation – Vented to the Outside..................................9–13
Step 2, Install Mounting Brackets............................................10
Step 3, Install the Hood ................................................................10
Step 4, Install Duct Bracket ........................................................11
Step 5, Connect Ductwork ..........................................................12
Step 6, Connect Electrical............................................................12
Step 8, Install Filters ......................................................................13
Step 9, Finalize Installation ........................................................13
Installation Instructions
Installation – Recirculating..................................................14–18
Step 2, Install Mounting Brackets............................................15
Step 3, Install the Hood ................................................................15
Step 5, Size Duct Piece..................................................................16
Step 6, Install Air Deflector Assembly....................................16
Step 7, Connect Electrical............................................................17
Step 9, Install Filters ......................................................................18
Step 10, Finalize Installation ......................................................18
36″ Minimum
24″ Minimum
30″ Maximum