AMD Sempron 3100+ SDA3100AIP3AX 전단
제품 코드
SDA3100AIP3AX
30430 Rev. 3.43 October 2004
AMD Athlon™ 64 Processor Power and Thermal Data Sheet
Chapter 3
AMD Sempron™ Desktop Processor
23
Table 20 AMD Sempron™ Processor Thermal/Power Specifications
Parameter/OPN
SDA3100AIP3AX
Model Number
3100+
CPUID 8000_0001h EAX [31:0]
7
00000FC0h
FID/VID Status MaxVID Field
8
04h
FID/VID Status MaxFID Field
8
0Ah
FID/VID Status StartVID Field
8
06h
FID/VID Status StartFID Field
8
0Ah
L2 Cache Size
256 KB
T
CASE
Max
10
70°C
T
CONTROL
Max
11
70°C
Max P-State
1800 MHz
VID_VDD
1.40 V
IDD Max
42.7 A
Thermal Design Power
1
62
W
Thermal Resistance (case-to-ambient)
9
0.45
°C/W
Intermediate P-State #1
N/A
VID_VDD N/A
IDD Max
IDD Max
N/A
Thermal Design Power
1
N/A
Intermediate P-State #2
N/A
VID_VDD N/A
IDD Max
IDD Max
N/A
Thermal Design Power
1
N/A
Intermediate P-State #3
N/A
VID_VDD N/A
IDD Max
IDD Max
N/A
Thermal Design Power
1
N/A
Min P-State
1000 MHz
VID_VDD 1.1
V
IDD Max
16.2 A
Thermal Design Power
1
20 W
Halt/Stop Grant at Max P-State
2
IDDC1 Max
30.0 A
I/O Power
5
2.2
W
Halt/Stop Grant at Min P-State
3
IDDC1 Max
7.0 A
I/O Power
5
2.2
W
S3
4
I/O Power
4,6
160 mW
Notes:
1. Thermal Design Power (TDP) is measured under the conditions of T
CASE
Max, IDD Max, and VDD=VID_VDD,
and include all power dissipated on-die from VDD, VDDIO, VLDT, VTT, and VDDA.
2. Assumes t
CASE
max, VDD, clock divider set to 32.
3. Assumes 50
°C, VDD nom, clock divider set to 32.
4. Assumes 35
°C, VDD, VDDA, and VLDT supplies are off, VDDIO and VTT are powered, memory in self-refresh
mode and DDR SDRAM interface tri-stated except CKE pins.
5. Thermal Design Power for VDDIO, VTT, VLDT, and VDDA power planes only.
6. Thermal Design Power for VDDIO and VTT power planes only.