GE RAG61 설치 설명서
9
Zoneline
®
Features Model Series
AZ
AZ
AZ
2200
3200
5200
Enhanced Dehumidification - Dry Air 25
Optional
N/A
N/A
Cooling EER Range (230 Volts/265 Volts)
9.6 - 11.6
9.6 - 11.6
10.0 - 12.0
Heating COP Range (230 Volts/265 Volts)
N/A
3.1 - 3.5
3.1 - 3.5
Heat Source - Electric Resistance Heat
Pages 52, 53
—
—
Heat Source - Heat Pump With
—
Std. Pages
—
Backup Resistance Heat
52, 53
Heat Source - Heat Pump With Selectable
Full Time or On Demand Simultaneous/
Full Time or On Demand Simultaneous/
—
—
Supplemental Resistance Heat
Quick Heat Recovery
Quick Heat Recovery
—
Std. - Page 14
Std. - Page 14
Heat Pump Defrost system
—
Passive
Reverse Cycle
Fan Motors - Permanently Lubricated
2
2
2
Standard Microprocessor Controls
Standard
Standard
—
Highly Featured Microprocessor Controls
—
—
Standard
Rotary Compressor
Standard
Standard
Standard
Automatic Compressor Restart Delay
Standard
Standard
Standard
Corrosion Treated (Not Available in 5KW Heater)
Optional
Optional
—
(Not Available in 265V, 2KW Heater)
Power Connection**
Included
Included
UPC*
Universal Heater
—
—
Standard
Reversible Indoor Air Louvers
Air Discharge
Air Discharge
Air Discharge
Angles: 40°/50°
Angles: 40°/50°
Angles: 40°/50°
Fan Cycle Switch
Standard
Standard
Standard
Indoor Fan Speed Selections - Hi/Low
Standard
Standard
Standard
Automatic Indoor Fan Speed
—
—
Standard
2 Speed Outdoor Fan
Standard
Standard
Standard
Fan Only Setting
Standard
Standard
Standard
Up-Front Filters
Standard
Standard
Standard
Concealed Manual Vent Control
Standard
Standard
Standard
Rotary Control Knobs
Standard
Standard
—
Touch Controls (Tactile Controls)
—
—
Standard
Electronic Temperature Selection
—
—
Standard
(Slews Up & Down) with Digital Display
Staged Heating
Staged Heating
—
—
Standard
Freeze Sentinel
TM
Standard
Standard
Standard
Automatic Emergency Heat
—
Standard
Standard
Electric Resistance Heat Lock-Out (above 46°F)
—
—
Standard
Temperature Limiting
Mechanical
Mechanical
7-Step
Electronic
Remote Control Capability With
Requires RAKOIM
Requires RAKOIM
Requires RAKOIM
Wall Mounted Thermostat
Page 16
Page 16
Page 16
Central Desk Control Capabilitys
Requires RAKOIM
Requires RAKOIM
Requires RAKOIM
With Load Shedding Option
Page 16
Page 16
Page 16
Ducted Installation Capability
RAK6052
RAK6052
—
Unit Diagnostics
—
—
Standard
Service Indicator
—
—
Temp Display Blinks
Internal Condensate Removal (ICR)
N/A
Optional
Optional
Factory Installed Option.
Cannot be used in Corrosion Areas.
Cannot be used in Corrosion Areas.
*UPC - Universal Power Cord Connection (See pages 38, 39 and 53)
**265 volt product. MUST be direct connected to meet National Electrical Code and all local codes.
Std. Pages
16, 53