Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. 
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust 
from cooking are drawn and f ltered by an optional charcoal f lter. The air is then purif ed and recirculated back 
within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct 
work, if possible. The hood is most effective and eff cient as an exhaust hood. Only when the exhaust option 
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a charcoal f lter is required on top of the decorative mesh f lter. 
Order according to its part number below. The decorative mesh f lter is intended to capture residue from 
cooking and the optional charcoal f lter helps to purify fumes exhausted from cooking for recirculation.
RECIRCULATING KIT (REQUIRED IF NOT DUCTED OUTSIDE THE HOME)
Kit includes charcoal f lter, brackets and return air vent.
Hood Model 
       Part No. 
       Filters in Pkg.
ZGE (all models)       ZRC-00GE             1
1.   Purchase recirculating kit per the part number above.
2.  Remove decorative mesh f lter from hood and place charcoal f lter on top of                                                                                                                
                               
mesh f lter.  Secure charcoal f lter to mesh f lter by using the supplied wire                                                            
brackets as shown in Fig.13.                                                
3.   Reinstall decorative mesh f lter.
                                                                                                                                                               
   
Charcoal Filter Replacement
Hood Model 
      Part No. 
  Qty to Order
ZGE (all models        Z0F-C0GE            1
Installation – 
Ductless Recirculation
4.  In order to recirculate the air properly, a return air vent must be installed to 
allow recycled air to be returned to the kitchen, Fig. 14.  Ducting must be run 
from the blower to the return air vent. The return air vent can be positioned 
on top of the cabinet or in a soff t/ceiling.                      
5.  Enable Charcoal Filter Change indicator on control panel. See page 15.
6. Charcoal  f lter must be replaced after every 120 hours of use or approximately 
every 3 to 4 months based on an average daily use of 1 hour of cooking time) 
The microprocessor in the controls, when set, will elapse and count usage 
time and indicate when charcoal f lter replacement is required every 120 hrs.