TROUBLE SHOOTING
17
1. 
Upon completion of installation, 
nothing works.
2.
Light is on but blowers are not 
turning at all or seems to be scraping on 
something.
3.
When blowers are on, something 
seems to be loose and spinning 
around inside.
4.
Vibration when blowers are on
5.
Blowers noise
6.
Light is not working
7.
No grease is collected in the residue 
containers
8.
No grease is collected in the residue 
containers after self cleaning.
9.
Safety grill are dirty
10.
Blowers seemed weak
Check if unit has been plugged in, make sure that all power 
has been turned back on and all electrical wiring are 
properly connected. 
Blower blade unit might have been mounted too low and 
scraping the bottom or jammed.  Loosen hex screw on 
blade unit and adjust to proper height.
There might have been foreign particles left within the 
discharge opening or rocks, leaves, branches, etc. that 
might have fell in from old duct work.  Disconnect duct work 
to inspect and remove any foreign particles.
Unit might not have been secured properly on cabinet.  Or 
cabinet might need to be further secured into studs on wall.
Our blowers are designed to perform up to 695 cfm.  A 
properly functioning motor itself should be relatively quiet.  
Nevertheless, due to vacuum created by the suction, noise 
level up to 5.5 sones will be generated when both blower 
unit is turned on at its maximum speed.  Employ both 
blowers at maximum  speed only when needed (heavy pan 
frying, wok cooking etc.)  Employing low speeds or a single 
blower will suffice moderate cooking such as steaming, 
broiling etc.
Light bulb might need to be replaced.  On some instances, 
the fragile bulb could have been damaged during the 
shipping process.  Simply replace with a 40 or 60W 
appliance bulb.
Grease flow will vary by the amount, methods and types of 
cooking.  If pan-frying is frequent accompanied by 
steaming, vapor from steam will liquefy accumulated 
grease in its internal housing and flows in the containers.
No grease collected in the residue containers is normal 
until the self clean function is completed.  Clean blowers 
approximately once a month as instructed to avoid 
clogging. 
Tubes connected to the internal housing might have been 
clogged due to lack of cleaning.  Or hood might not have 
been leveled when installed.  Unclog tubes or re-install 
hood (refer page 16).
The self clean feature cleans only the internal housing 
within the range hood.  Remove safety grill to clean in 
dishwasher and clean all surface periodically as instructed.
Check duct size used, duct size should be at least 6“ or 3-
1/4 x 10”.  Range hood WILL NOT function properly with 
the insufficient duct size.
Check if duct is clogged or if damper unit is not opening 
properly.  A tight mesh on a side wall cap unit might also 
cause restriction to the air flow.