Summit SPR315OSCSS 사용자 매뉴얼

다운로드
페이지 16
 
11 
 
ºF/ºC
 Selector 
Select the temperature display setting in Fahrenheit or Celsius degree. To change the temperature 
from Fahrenheit to Celsius or from Celsius to Fahrenheit, press and hold the SUPERFREEZE key 
for 5 seconds. 
 
Setting the Temperature Control 
•  You can set the temperature by pressing the UP and DOWN keys. When you press either of the 
two keys for the first time, the LED readout will show the original temperature set previously. 
(The temperature preset at the factory is 0°F (-18°C). 
•  The temperature you are setting will increase by one degree each time you press the UP key, 
and will decrease by one degree each time you press the DOWN key. 
•  The range of the temperature control is from -11°F to 11°F. 
•  To view the set temperature at any time, press the UP or DOWN key. The set temperature will 
flash in the display window for 5 seconds. After 5 seconds, the temperature inside the unit will 
reappear in the display window. 
 
Interior Light 
The unit is equipped with an interior LED light which will be turned ON when the door is open. 
 
 
 
 
 
 
 
 
 
 
SABBATH MODE 
Sabbath mode is available for the observance of certain religious holidays. This mode turns off the 
displays, interior light and audible alarms and prevents them from turning on again. Normal cooling 
operations will still take place. 
 
To initiate Sabbath mode, press the POWER and LIGHT keys at the same time for at least 5 seconds for 
FF1538B/SPR315OS/SPR626OS or press the POWER and SUPERFREEZE keys at the same time for at 
least 5 seconds for SCFF1537B/SCFF51OS/SCFF51OSWH. The indicator light will flash four times and 
confirm the Sabbath mode is ON. 
Sabbath mode can be exited by repeating the above process. The Sabbath Mode will automatically turn 
off after 96 hours. 
 
TEMPERATURE MEMORY FUNCTION 
 
• 
In the event of a power interruption
 (power surge, breaker switch, etc.)
, the unit can remember the 
previous temperature settings, and when the power is recovered, the cabinet temperature will return 
to the same setting temperature as before the power went off.
 
 
DEFROSTING 
 
•  The unit defrosts automatically in normal operating conditions. 
NOTE: 
•  If the unit is unplugged, or power is lost or turned off, you must wait 3 to 5 minutes before 
restarting the unit. If you attempt to restart before this time delay, the unit will not start. 
•  When you use the unit for the first time or restart the unit after it has been shut off for a long time, 
there could be a few degrees variance between the temperature you select and the one indicated 
on the LED readout.  This is normal and is due to the length of the activation time. There should 
not be a problem once the unit has been running for a few hours.